Read Sharp MX-C380P / MX-C400P / MX-B380P / MX-B382P / MX-B400P (serv.man6) Service Manual online
MX-C400P/C380P, MX-B400P/B380P/B382P SIMULATION 5 – 40
43-22
Purpose
Adjustment/Setup
Function (Purpose) Used to set the environment correction
under low temperature and low humidity (L/
L) for the fusing temperature setting (SIM
43-4) in each paper mode.
L) for the fusing temperature setting (SIM
43-4) in each paper mode.
Section
Operation/Procedure
1) Select an item to be set.
2) Set the set value. (Enter the set value, and press [OK] key and
1) Select an item to be set.
2) Set the set value. (Enter the set value, and press [OK] key and
OSA shortcut key.)
Correction value: -49 - +49, 1 Count = 1
C Change
• MX-C400P/C380P
• MX-B400P/B380P
<Code descriptions>
Correction value
-49
-25
-5
0
5
25
49
Input value
1
25
45
50
55
75
99
Item/Display
Content
Setting
range
Group
A
Group
B
Group
C
A
HL_UM PLAIN PAPER BW DUP LL
Black-White plain paper duplex TH_UM set value
1 - 99
55
55
55
B
HL_LM PLAIN PAPER BW DUP LL
Black-White plain paper duplex TH_LM set value
1 - 99
55
55
55
C
HL_E PLAIN PAPER BW DUP LL
Black-White plain paper duplex TH_E set value
1 - 99
55
55
55
D
PLAIN PAPER BW DUP APP CNT LL
Black-White plain paper duplex fusing temperature application start
image screen number
image screen number
1 - 99
50
50
50
E
HL_UM PLAIN PAPER CL DUP LL
Color plain paper duplex TH_UM set value
1 - 99
55
55
55
F
HL_LM PLAIN PAPER CL DUP LL
Color plain paper duplex TH_LM set value
1 - 99
55
55
55
G
HL_E PLAIN PAPER CL DUP LL
Color plain paper duplex TH_E set value
1 - 99
55
55
55
H
PLAIN PAPER CL DUP APP CNT LL
Color plain paper duplex fusing temperature application start image
screen number
screen number
1 - 99
50
50
50
I
HL_UM HEAVY PAPER BW DUP LL
Black-White heavy paper duplex TH_UM set value
1 - 99
55
J
HL_LM HEAVY PAPER BW DUP LL
Black-White heavy paper duplex TH_LM set value
1 - 99
55
K
HL_E HEAVY PAPER BW DUP LL
Black-White heavy paper duplex TH_E set value
1 - 99
55
L
HEAVY PAPER BW DUP APP CNT LL
Black-White heavy paper duplex fusing temperature application start
image screen number
image screen number
1 - 99
50
M
HL_UM HEAVY PAPER CL DUP LL
Color heavy paper duplex TH_UM set value
1 - 99
55
N
HL_LM HEAVY PAPER CL DUP LL
Color heavy paper duplex TH_LM set value
1 - 99
55
O
HL_E HEAVY PAPER CL DUP LL
Color heavy paper duplex TH_E set value
1 - 99
55
P
HEAVY PAPER CL DUP APP CNT LL
Color heavy paper duplex fusing temperature application start image
screen number
screen number
1 - 99
50
Item/Display
Content
Setting
range
Group
A
Group
B
Group
C
A
HL_UM PLAIN PAPER BW DUP LL
Plain paper duplex TH_UM set value
1 - 99
55
55
55
B
HL_LM PLAIN PAPER BW DUP LL
Plain paper duplex TH_LM set value
1 - 99
55
55
55
C
HL_E PLAIN PAPER BW DUP LL
Plain paper duplex TH_E set value
1 - 99
55
55
55
D
PLAIN PAPER BW DUP APP CNT LL
Plain paper duplex fusing temperature application start image screen
number
number
1 - 99
50
50
50
E
HL_UM HEAVY PAPER BW DUP LL
Heavy paper duplex TH_UM set value
1 - 99
55
F
HL_LM HEAVY PAPER BW DUP LL
Heavy paper duplex TH_LM set value
1 - 99
55
G
HL_E HEAVY PAPER BW DUP LL
Heavy paper duplex TH_E set value
1 - 99
55
H
HEAVY PAPER BW DUP APP CNT LL
Heavy paper duplex fusing temperature application start image screen
number
number
1 - 99
50
TH_UM
Fusing upper thermistor (center)
TH_LM
Fusing lower thermistor
TH_E
Fusing thermistor (external heat roller)
HL_UM
Heater lamp upper
HL_LM
Heater lamp lower
HL_E
Heater lamp (external heat roller)