MX-B382 (serv.man7). INSTALLATION MANUAL - Sharp Copying Equipment Service Manual (repair manual). Page 57

Read Sharp MX-B382 (serv.man7) Service Manual online

MX-B382/B402  DEHUMIDIFIER HEATER KIT (SERVICE PARTS) FOR THE MX-CSX1/CSX2  14 – 5
3)
Cut the inside section of the rear cabinet where the harness
passes through.
J. High temperature caution label attachment
1)
Pull out the paper tray 1, and clean the caution label attach-
ment section with alcohol.
2)
Attach the caution label (which is packed together with the
dehumidifier heater kit for the main unit) to the paper tray.
K. Attach the rear cabinet.
3. Check after installation
1)
Turn ON the dehumidifier heater switch. (Press the upper sec-
tion of the switch.)
2)
Measure the resistance between the earth terminal and the AC
terminal at the lead edge of the AC cord with a tester, and
check to confirm that the resistance is infinite.
* Check the resistance between the non-grounding side (Live)
and the grounding side and between the non-grounding side
(Neutral) and the grounding side.
* If there is conduction between the grounding terminal and
the AC terminal, the harness on the primary side may be in
contact with the grounding wire (the wire may be pinched or
in some trouble). In this case, disassemble it again and
check to confirm that there is no pinching or wiring mistake.