MX-B382 (serv.man7). INSTALLATION MANUAL - Sharp Copying Equipment Service Manual (repair manual). Page 51

Read Sharp MX-B382 (serv.man7) Service Manual online

MX-B382/B402  DEHUMIDIFIER HEATER KIT (SERVICE PARTS) FOR THE MAIN UNIT  13 – 3
G. Installation of the dehumidifier heater unit to 
the main unit.
1)
Pull out the paper tray, and pass the harness of the dehumidi-
fier heater through the hole in the upper section of the lift-up
unit.
For the 200V series, pass the WH earth harness 200 through
the hole in the upper section of the lift-up unit.
2)
Engage the pawls of the dehumidifier heater unit with the
square holes (4 positions) in the metal plate of the main unit.
3)
Fix the dehumidifier heater installation plate FT with the M3 x 6
screw (No.10).
* At that time, arrange so that the rear section of the dehumid-
ifier heater installation plate FT is on the lift-up unit.
4)
Pass the harness of the dehumidifier heater through the wire
saddle.
5)
Connect the connector of the dehumidifier heater harness to
CN3 of the WH PWB.
6)
Pass the WH earth harness 200 through three clamps of the
machine. (200V series only)
7)
Fix the terminal of the WH earth harness 200 to the machine
frame with the M3 x 8 screw (No. 12).
When installing the dehumidifier heater kit to the MX-CSX1/
CSX2, hereinafter perform the operations described on the
chapter of "[15] DEHUMIDIFIER HEATER KIT (SERVICE
PARTS) OF THE MX-CSX1/CSX2."
When the MX-CSX1/CSX2 is not installed, or when the MX-
CSX1/CSX2 is installed but the dehumidifier heater kit is not
installed to the MX-CSX1/CSX2, perform the procedures from
item H below.
H. Dehumidifier heater resistance check
1)
Insert a tester between pin 1 and pin 3 of CN3 of the WH PWB,
and check to confirm that the resistance is as shown below.
120V series: 2.304K
 - 3.456K
230V series: 4.232K
 - 6.348K
Lift up unit
200V Only
Page of 60
Display