Read Sharp MX-B382 (serv.man4) Handy Guide online
Maintenance
14
SHARP
Document Solution Centre
Maintenance Indications
:
Maintenance Required: TA
Maintenance [All] Counter has reached
specified limit
Maintenance Required: VK
Black Developer (Counter) has
reached the specified life.
Replace Black Developer.
Process
Section
(Developer)
Change the Supplies:
Drum Cartridge
Black Drum (Counter) has reached
the specified life.
Replace Black Drum Unit.
Process
Section
(Drum)
Change the Supplies:
Fusing Unit
Fuser Unit Print (Counter) has
reached the specified limit.
Replace the Heat Roller and Cleaner
Roller Kits or Fuser Unit.
Fuser
Section
Change the Supplies:
Primary Transfer Belt Unit
Primary Transfer Unit (Counter) has
reached the specified limit.
Replace Primary Transfer Belt Kit
or Primary Transfer Belt Unit.
Transfer
Section
Change the Supplies:
Secondary Transfer Belt Unit
Secondary Transfer Unit (Counter)
has reached the specified limit.
Replace the Secondary Transfer
Roller Unit.
Starting Powder:
The following starting powder should be applied to the relevant consumable item during
maintenance:-
maintenance:-
Starting Powder
OPC Drum
Primary Transfer Belt
MX-B382(P)
UKOG-0312FCZZ
[Stearic Acid]
UKOG-0123FCZZ
[Kynar Starting Powder]
CAUTION:
Do not apply Stearic Acid (UKOG-0312FCZZ), Strontium Titanium (UKOG-0316FCZZ) or Titanium
Hydroxide (UKOG-0322FCZZ) starting powder to the Primary Transfer Belt.
Hydroxide (UKOG-0322FCZZ) starting powder to the Primary Transfer Belt.