MX-B381/B401 SIMULATION 5 – 53
*1: When REFRESH MODE setting is enabled (0), the menu of the user process control execution button is displayed on the user system
setting menu.
When the density change is not within the allowable range, the user can perform the process control manually and forcibly. However, toner
is consumed grater than as usual. This point must be explained to the user clearly.
When the density change is not within the allowable range, the user can perform the process control manually and forcibly. However, toner
is consumed grater than as usual. This point must be explained to the user clearly.
Mode
Item/Display
Content
Setting range
Default
value
Process control
Enable/Disable
setting
Enable/Disable
setting
A
INITIAL
YES
When warm-up after clearing the
counter of the OPC drum and the
developer unit
counter of the OPC drum and the
developer unit
Enable
0 - 1
0
0
NO
Disable
1
B
SW ON
When supplying the power (when
clearing shut-off.)
clearing shut-off.)
Process control Disable
1 - 3
1
3
BK process control Enable
2
Pixel count judgment
(Judgment is based on the
setting value of item K, L.)
(Judgment is based on the
setting value of item K, L.)
3
C
TIME
After passing the specified time from
leaving READY continuously (Time can
be changed by INTERVAL TIME)
leaving READY continuously (Time can
be changed by INTERVAL TIME)
Process control Disable
1 - 3
1
3
BK process control Enable
2
Pixel count judgment
(Judgment is based on the
setting value of item K, L.)
(Judgment is based on the
setting value of item K, L.)
3
D
HUM_LIMIT
HUM judgment is made when turning
ON the power and after passing TIME.
ON the power and after passing TIME.
Process control Disable
1 - 2
1
2
BK process control Enable
2
E
HUM
The temperature and humidity in side
the machine are monitored only during
a job for every 2hours (set by item N).
When the changes in the temperature
and the humidity are greater than the
specified level (the set value of item O)
in comparison with the previous
process control.
the machine are monitored only during
a job for every 2hours (set by item N).
When the changes in the temperature
and the humidity are greater than the
specified level (the set value of item O)
in comparison with the previous
process control.
Process control Disable
1 - 2
1
2
BK process control Enable
2
F
REV1
YES
The accumulated traveling distance of
BK or M position OPC unit reaches the
specified level after turning the power.
BK or M position OPC unit reaches the
specified level after turning the power.
Enable
0 - 1
0
0
NO
Inhibit
1
G
REV2_BK
YES
The accumulated traveling distance of
BK position OPC drum unit reaches the
specified level from execution of the
previous density correction.
BK position OPC drum unit reaches the
specified level from execution of the
previous density correction.
Enable
0 - 1
0
0
NO
Inhibit
1
H
REFRESH
MODE(*1)
MODE(*1)
YES
Select of YES/NO of the manual
process control key with key operation
process control key with key operation
Key operation display
0 - 1
0
1
NO
Key operation NO display
1
I
DAY
When the next warm-up if there is no
job after a job after passing the
specified days from execution of the
previous process control
job after a job after passing the
specified days from execution of the
previous process control
Disable of the specified
days judgment
days judgment
0 - 999
0
1
1 - 999 days passing
1 - 999
Process control
conditions
setting
conditions
setting
J
PIX_RATIO_BK
Magnification ratio setting (%) of the BK toner count specified value
entry of 100 corresponds to 1k of A4 5% print.
entry of 100 corresponds to 1k of A4 5% print.
1 - 999
10
K
INTERVAL TIME
Passing time setting of "TIME" (h: hour)
1-255
(1-255: 1-255h passed)
12
L
HUM HOUR
Interval setting of the temperature and humidity monitoring time of
"HUM" (h: hour)
"HUM" (h: hour)
1 - 24
2
M
HUM_DIF
Area difference specified value when compared with the execution of
the previous process control of "HUM”
the previous process control of "HUM”
1 - 9
2
N
BK_RATIO
Magnification ratio setting (%) of the specified value of the BK position
OPC drum traveling distance of "REV2_BK”
OPC drum traveling distance of "REV2_BK”
1-999
(Entry of 20 corresponds
to 100,000mm.)
15
O
HT_DIF
Bias change difference value used for judgment of HT process control
1 - 255
40
Secondary
transfer
cleaning setting
transfer
cleaning setting
P
2TRAN_CLEAN_TIME1
Secondary transfer cleaning process time judgment threshold value 1
1 - 999
200
Q
2TRAN_CLEAN_TIME2
Secondary transfer cleaning process time judgment threshold value 2
1 - 999
300
R
2TRAN_CLEAN_TIME3
Secondary transfer cleaning process time judgment threshold value 3
1 - 999
500
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
7(67
352&217,0,1*$'-8670(17
$˖
˷̚˹
˖,1,7,$/<(6
$˖
˖6:21
%˖
˖7,0(
&˖
˖+80B/,0,7
'˖
˖5(912
)˖
˖+80
(˖
˖5(9B%.<(6
*˖
˖5()5(6+02'(12
+˖
˖'$<
,˖
˖3,;B5$7,2B%.
-˖
˖,17(59$/7,0(
.˖
˖+80+285
/˖
2.