Read Sharp MX-B381 / MX-B401 (serv.man7) Service Manual online
MX-B381/B401 SIMULATION 5 – 48
44-9
Purpose
Operation data display
Function (Purpose) Used to display the result data of the high
density process control operation.
Section
Image process (Photo-conductor/
Developing/Transfer/Cleaning)
Developing/Transfer/Cleaning)
Operation/Procedure
1)
1)
Select a target display mode.
(*1) Differs depending on the destination.
(*2) Value on the left: Voltage level after correction Value on the right: Base voltage level
(*2) Value on the left: Voltage level after correction Value on the right: Base voltage level
Mode
Item/Display (*: Correction value)
Content
Display
range
Default
value
CPY/PRN
(*2)
P (PROCON)
BLACK : GB ***/*** DV ***/***
High density process control GB/DV data
(Actual output voltage level/base voltage level)
(Actual output voltage level/base voltage level)
GB: 150 - 850
DV: 100 - 600
DV: 100 - 600
GB: 630
DV: 430
DV: 430
N(M)
(NORMAL (MIDDLE))
BLACK : GB ***/*** DV ***/***
High density normal (Medium speed display)
GB/DV data
(Actual output voltage level/base voltage level)
GB/DV data
(Actual output voltage level/base voltage level)
GB: 150 - 850
DV: 100 - 600
DV: 100 - 600
GB: 630
DV: 430
DV: 430
N(L)
(NORMAL (LOW))
BLACK : GB ***/*** DV ***/***
High density normal (Low speed display)
GB/DV data
(Actual output voltage level/base voltage level)
GB/DV data
(Actual output voltage level/base voltage level)
GB: 150 - 850
DV: 100 - 600
DV: 100 - 600
GB: 600
DV: 400
DV: 400
OTHER
TN/TC
TN HUD AREA
Toner control display humidity area
1 - 14
9
TN HUD DATA
Toner control display humidity AD value
0 - 1023
0
TC TMP AREA
Transfer display temperature area
1 - 9
4
TC TMP DATA
Transfer display temperature AD value
0 - 1023
0
TC HUD AREA
Transfer display humidity area
1 - 9
4
TC HUD DATA
Transfer display humidity AD value
0 - 1023
0
MD HUD AREA
Membrane decrease display humidity area
1 - 14
9
MD HUD DATA
Membrane decrease display humidity AD value
0 - 1023
0
DRUM
MD K STEP
Drum membrane decrease correction STEP
display
display
0 - 4
0
MD K DRUM COUNTER
Membrane decrease drum traveling distance
area
area
0 - 20
0
VG
MD K REVISE(VG) : L *** M ***
Drum membrane decrease grid voltage
correction display
correction display
0 - 255
0
LD
MD K REVISE(LD) : L *** M ***
Drum membrane decrease laser power voltage
correction
correction
0 - 255
0
HV
MD K REVISE(HV) : L *** M ***
High density membrane decrease environment
GB correction display
GB correction display
0 - 255
0
CP
MD K REVISE(CP) : L *** M ***
Drum membrane decrease environment grid
voltage correction display
voltage correction display
0 - 255
0
DL
MD K REVISE COL (DL): L *** M ***
Drum membrane decrease discharge light
quantity correction (%)
quantity correction (%)
0 - 100
50
DL EV
MD K REVISE COL (DL EV): L *** M ***
Drum membrane decrease environment
discharge light quantity correction (%)
discharge light quantity correction (%)
-100 - 100
0
CRUM
DESTINATION
Machine side management CRUM destination
(Main unit data)
(Main unit data)
-
CRUM
information
(*1)
MODEL TYPE
Machine model type
0 - 1
0
CRUM DEST_K
CRUM destination (CRUM data)
-
CRUM
information
(*1)
OTHER
CNT
PROCON COUNT HV
High density process control number of
executions
executions
0 - 99999999
0
PROCON COUNT HT
Half tone process control number of executions
0 - 99999999
0
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
7(67
352&21'$7$',63352&211250$/01250$//
%/$&.B3*%B'9B
%/$&.B0*%B'9B%/$&.B/*%B'9B
27+(5
&3<351