MX-B201D (serv.man8). MX-FX12 Service Manual - Sharp Copying Equipment Service Manual (repair manual). Page 18

Read Sharp MX-B201D (serv.man8) Service Manual online

MX-FX12  FAX SOFT SWITCH  2 - 13
S
W
44
1
Sending speed
Used to set the speed of fax sending. 
* If SW43, B1 is off (V.34 mode is off)
  and if SW44, B1-4 is less than 6 (not V.34)
    ---> operate it at speed set in SW44, B1-4.
* If SW43, B1 is off (V.34 mode is off)
  and if SW44, B1-4 is over than 7 (V.34)
    ---> operate it at speed set in SW44, B1-4=5.
          V.17-14.4Kbps
* If SW43, B1 is on (V.34 mode is on)
  and if SW44, B1-4 is less than 6 (not V.34)
    ---> operate it at speed set in SW44, B1-4=V.34-33.6Kbps.
* If SW43, B1 is on (V.34 mode is on)
  and if SW44, B1-4 is over than 7 (V.34)
    ---> operate it at speed set in SW44, B1-4
33.6 K bps -> 
V.34
1
2
1
3
1
4
0
Bit No.
1
2
3
4
0: 2.4 K bps -> V.27ter
0
0
0
0
1: 2.4 K bps -> V.27ter
0
0
0
1
2: 4.8 K bps -> V.27
0
0
1
0
3: 7.2 K bps -> V.29
0
0
1
1
4: 9.6 K bps -> V.29
0
1
0
0
5: 12  K bps -> V.17
0
1
0
1
6: 14.4 K bps -> V.17
0
1
1
0
7: 16.8 K bps -> V.34
0
1
1
1
8: 19.2 K bps -> V.34
1
0
0
0
9: 21.6 K bps -> V.34
1
0
0
1
10: 24.6 K bps -> V.34
1
0
1
0
11: 26.4 K bps -> V.34
1
0
1
1
12: 28.8 K bps -> V.34
1
1
0
0
13: 31.2 K bps -> V.34
1
1
0
1
14: 33.6 K bps -> V.34
1
1
1
0
15: 33.6 K bps -> V.34
1
1
1
1
5
Reception speed
Used to set the speed of fax receiving.
* If SW43, B1 is off (V.34 mode is off)
  and if SW44, B5-8 is less than 6 (not V.34)
    ---> operate it at speed set in SW44, B5-8.
* If SW43, B1 is off (V.34 mode is off)
  and if SW44, B5-8 is over than 7 (V.34)
    ---> operate it at speed set in SW44, B5-8=5.
          V.17-14.4Kbps
* If SW43, B1 is on (V.34 mode is on)
  and if SW44,B5-8 is less than 6 (not V.34)
    ---> operate it at speed set in SW44, B5-8=V.34-33.6Kbps.
* If SW43, B1 is on (V.34 mode is on)
  and if SW44, B5-8 is over than 7 (V.34)
    ---> operate it at speed set in SW44, B5-8
33.6 K bps -> 
V.34
1
6
1
7
1
8
0
Bit No.
5
6
7
8
0: 2.4 K bps -> V.27ter
0
0
0
0
1: 2.4 K bps -> V.27ter
0
0
0
1
2: 4.8 K bps -> V.27
0
0
1
0
3: 7.2 K bps -> V.29
0
0
1
1
4: 9.6 K bps -> V.29
0
1
0
0
5: 12  K bps -> V.17
0
1
0
1
6: 14.4 K bps -> V.17
0
1
1
0
7: 16.8 K bps -> V.34
0
1
1
1
8: 19.2 K bps -> V.34
1
0
0
0
9: 21.6 K bps -> V.34
1
0
0
1
10: 24.6 K bps -> V.34
1
0
1
0
11: 26.4 K bps -> V.34
1
0
1
1
12: 28.8 K bps -> V.34
1
1
0
0
13: 31.2 K bps -> V.34
1
1
0
1
14: 33.6 K bps -> V.34
1
1
1
0
15: 33.6 K bps -> V.34
1
1
1
1
SW 
NO.
Data 
No.
Item
Switch selection and contents of functions
Initial value
Remark