Read Sharp MX-B201D (serv.man7) Service Manual online
MX-NB11 TROUBLE CODE 9 - 2
F6
60
Content AFAX plug detect error
(When MX-FX12 is installed)
Detail
For USB connection with AFAX, ANB cannot
detect the connection with AFAX.
detect the connection with AFAX.
Cause
USB connected error between ANB and
AFAX
AFAX
Check
and
remedy
and
remedy
Replace the ANB PWB or AFAX PWB.
90
Content AFAX USB communicate error
(When MX-FX12 is installed)
Detail
For interface, ANB cannot be communicated
with AFAX.
with AFAX.
Cause
Interface error between ANB and AFAX
Check
and
remedy
and
remedy
Check the connection between ANB and
AFAX.
Replace the ANB PWB or AFAX PWB.
AFAX.
Replace the ANB PWB or AFAX PWB.
92
Content ANB flash error (When MX-FX12 is installed)
Detail
Can not read /write to Flash ROM on the
ANB PWB.
ANB PWB.
Cause
Access error to Flash ROM.
Check
and
remedy
and
remedy
Replace the ANB PWB.
94
Content AFAX register error
(When MX-FX12 is installed)
Detail
Can not access to MODEM on the AFAX
PWB.
PWB.
Cause
Access error to MODEM
Check
and
remedy
and
remedy
Replace AFAX PWB.
U1
03
Content Network board battery error
Details
The RTC backup battery voltage on network
PWB falls.
PWB falls.
Cause
The RTC backup battery voltage on network
PWB falls.
PWB falls.
Check
and
remedy
and
remedy
Check voltage of the RTC back up battery.
Replace the battery.
Replace the battery.
Main
code
code
Sub
code
Details of trouble
Click on the first or last page to see other MX-B201D (serv.man7) service manuals if exist.