MX-B200 FLASH ROM VERSION UP PROCEDURE 16-3
3)  Check that the following display is shown. 
Select "Install from a list or the specific location" and press the NEXT
button. 
4)  Select "Include this location in the serch". If the retrieval area does
not include the folder which includes the maintenance tool driver
(Mainte.inf), select "Browse"
If the folder path is properly shown, press the NEXT button to go to
procedure 7).
5) Select the folder which includes the maintenance tool driver
(Mainte.inf), and press the OK button. 
(When the driver is included in the "C:\" folder:)
6)  Check that the path to the folder which includes the maintenance
tool driver (Mainte.inf) is shown, and press the NEXT button. 
7)) Check that the following display is shown. Press the Continue
Anyway button.
8) When installation is completed, the following display is shown.
Press the Finish button.
The installation procedure (on Windows XP) is completed with the above
operation. 
C. Installation procedure on Windows 2000
1) Machine side:
Executable by performing the Service Simulation No. 49-01 (Flash
Rom program-writing mode).
(A word "d" appears on the operation panel to denote the download
mode status. )
2) Connect the machine and the PC with a USB cable.