MX-B200 (serv.man5). Service Manual - Sharp Copying Equipment Service Manual (repair manual). Page 117

Read Sharp MX-B200 (serv.man5) Service Manual online

MX-B200 FLASH ROM VERSION UP PROCEDURE 16-1
[16] FLASH ROM VERSION UP PROCEDURE
1.Preparation
Write the download data (the file with the extension dwl) to the main
body.
Necessary files for download
• Maintenance.exe (Maintenance software) 
• ProcModelH_AJ.mdl
• ProcModelH_AJ.ini
• ProcModelH_AJ.fmt
• Mainte.inf
• Usbscan.sys
• Download file:***.dwl
<Note>
•The Download file(***.dwl ) and the like that are to be downloaded
should be copied, in advance, into folders that have a maintenance
program.
•When creating a folder for a maintenance tool in the PC, be sure that no
lengthy folder name is included in the path.
(Example)
Incorrect  c:\Maintenance Download Tool
Correct    c:\Maintenance\Downtool
2.Download procedure
1) Main body side: 
Executable by performing the Service Simulation No. 49-01 (Flash
Rom program-writing mode).
(A word "d" appears on the operation panel to denote the download
mode status. )
2) Connect the PC and the main body with the download cable 
(USB cable).
3) PC side:
Boot the maintenance program. Select the model icon.
<Sample display>
4) PC side: 
Confirm that the "Simulation Command List" tree is displayed on the
maintenance program.
5) PC side:
When the message "the main body has not got started running" is
displayed on the lowest area of the figure below after the
"maintenance program" is started up, select the "File" and then
"Reconnect" in the menu bar.
6) PC side:
Confirm a tree is displayed under the "Special (MCU)" on the
maintenance program". (If no tree is displayed, confirm that the USB
is connected and select the "Reconnect" (the above 5) again.)
Page of 123
Display

Click on the first or last page to see other MX-B200 (serv.man5) service manuals if exist.