MX-6580N, MX-7580N. MX7580N - Handy Guide Version November 2017 - NOTE - Handy Guides are NOT a substitute for Service Manuals and Parts Guides - Sharp Copying Equipment Handy Guide. Page 20

Read Sharp MX-6580N / MX-7580N Handy Guide online

MAINTENANCE 
SHARP  
 
MX-6580N/7580N Handy Guide Nov’17 
SHARP Office Solutions Group 
Page 20
/76 
 
 
 
 
IMAGE QUALITY ADJUSTMENTS (After Replacement Described Above): 
 
 
Sim 44-02 
Image Density & Registration Sensor Adjustment. 
 
 
Sim 44-06 
Process Control execution. 
 
 
Sim 44-26 
Half tone process control execution. 
 
 
Sim 50-22 
Drum Position & Registration Adjustment - select ALL. 
 
 
Sim 61-13 
Clear laser F/R density correction data. 
 
 
Sim 61-11 
Laser F/R density variation correction execution. 
 
 
Sim 46-74  
Automatic Colour Balance Adjustment (Copy & Printer). 
 
 
Sim 46-01  
Adjust Copy Exposure Density (Colour). 
 
 
Sim 46-02 
Adjust Copy Exposure Density (B/W).  
 
 
 
Every 
300K 
Every 
600K 
PROCESS SECTION:  
In addition to Total / K schedule (and/or colour schedule when indicated):- 
 
 
Replace PTC unit (MX-620CU):- 
• 
PTC Charger Wire 
• 
PTC Cleaner 
• 
PTC Cleaner B
 
 
 
Replace Ozone Filter Kit (MX-620FL):- 
• 
Ozone Filters 
• 
Toner Filters 
• 
Deodorant Filter  
 
 
Sim 24-04  
Clear OZONE/TONER FILTER Counters (Total & Day). 
 
 
Sim 24-04  
Clear PTC Counters (Total, Day & Rotation). 
 
 
 
 
Clear PTC CLEAN Counter. 
 
 
 
 
 
REAR FRAME SECTION: 
 
 
Check Process Unit Main Drive Units (BK, C, M & Y) – 
apply grease to drive gears  
[UKOG-0307FCZZ].
 
 
 
 
 
 
SCANNER SECTION: 
 
 
Clean Platen Glass, Mirrors, CCD, and white reference plate. 
 
 
Clean RSPF Scanning Glass. 
 
 
 
 
 
PAPER FEED & TRANSPORT SECTION: 
 
 
Replace Paper Dust Removal Unit (MX-620PD) 
 
 
Check/Clean ALL Paper Path Sensors (including Duplex unit). 
 
 
Check/Clean ALL PF Transport Rollers. 
 
 
Check/Clean BYPASS TRAY PF Rollers (check tray counter using Sim 22-09). 
Replace every 100k or after 1 year. 
 
 
Check/Clean ALL TRAY PF Rollers (check tray counter using Sim 22-09). 
Replace every 200k (individual tray) or after 1 year. 
 
 
Sim 24-04  
Clear PS PAPER Counters (Total & Day). 
 
 
Sim 24-02  
Clear Individual Tray Counter (only after PF roller replacement) 
 
 