Read Sharp MX-6580N / MX-7580N (serv.man2) Handy Guide online
mSATA SSD REPLACEMENT PROCEDURE
SHARP
50
Some data that is stored on the mSATA SSD can be backed up and reinstalled following replacement or
failure. If the mSATA SSD is operating normally before replacement, backup the data and then reinstall the
data onto the replacement mSATA SSD.
failure. If the mSATA SSD is operating normally before replacement, backup the data and then reinstall the
data onto the replacement mSATA SSD.
The mSATA SSD contains the following data:-
No.
Data
Backup Method
Data Reinstall Method
Reinstall
Operator
1
ICU firmware/ Snapshot
---
SIM49-01
Service
2
Font / Web Help
---
SIM49-01
Service
3
Option Font ROM
---
SIM49-01
Service
4
e-Manual
---
SIM49-03
Service
5
Watermark
---
SIM49-05
Service
6
OCR dictionary data
---
SIM49-06
Service
7
Backup data
---
---
---
8 System setting value data file
SIM56-02/ Device cloning /
Storage backup
SIM56-02/ Device cloning /
Storage backup
Service or
User
9
FAX/I-FAX reception image
data (backup)
SIM66-62
---
---
mSATA SSD Replacement Procedure:
1. Back up the mSATA SSD data before replacement:-
• Use SIM56-02 to back up the data onto a USB memory device.
• Use Device Cloning function to back up the mSATA data when the operation panel screen has
• Use Device Cloning function to back up the mSATA data when the operation panel screen has
been customised.
2. Replace the mSATA SSD.
3. Power on / Boot the MFP Device:
4. Install/Update the Engine firmware using SIM49-01.
5. Install the E-Manual Data onto the HDD using SIM49-03.
6. Install Watermark data onto the HDD using SIM49-05:
U2-60 trouble will be displayed when no Watermark data is present. After installing the Watermark
data, reboot the MFP and cancel U2-60 trouble by executing SIM16.
data, reboot the MFP and cancel U2-60 trouble by executing SIM16.
7. Install OCR dictionary data onto the HDD using SIM49-06:
U2-70 trouble will be displayed when no OCR data is present. After installing the OCR dictionary data,
reboot the MFP and cancel U2-70 trouble by executing SIM16.
reboot the MFP and cancel U2-70 trouble by executing SIM16.
8. Import the storage data backed up in Step 1.
• Use SIM56-02 and/or device cloning function to import the mSATA SSD back up data.