MX-6500N, MX-7500N (serv.man20). Section 6 Simulation - Sharp Copying Equipment Service Manual (repair manual). Page 125

Read Sharp MX-6500N / MX-7500N (serv.man20) Service Manual online

MX-7500N  SIMULATION  6 – 125
 
61-4
Purpose
Adjustment
Function (Purpose)
Used to print the print image skew adjust-
ment pattern. (LSU unit)
Section
Operation/Procedure
1) Select a target item with scroll key on the touch panel.
2) Enter the print conditions setting value with 10-key.
3) Press [EXECUTE] key.
The print image skew adjustment pattern is printed.
 
61-11
Purpose
Adjustment
Function (Purpose)
Used  to  correct  the  laser  power  automati-
cally.
Section
Operation/Procedure
1) Select a target item with touch panel key.
2) Press [AUTO CORRECTION] key.
3) Select the adjustment density pattern.
4) Press [EXECUTE] key.
5) The adjustment pattern is printed out.
6) Place  the  printed  adjustment  pattern  on  the  document  table
(A4R direction), and press [EXECUTE] key.
The automatic correction of the laser power is performed, and
then the adjustment result pattern is outputted.
7) To perform the correction again, press [RETRY] key.
8) When [DATA] key is pressed on the initial screen, the display is
shifted to the automatic adjustment result display screen.
 
61-12
Purpose
Adjustment
Function (Purpose)
Laser power manual correction
Section
Operation/Procedure
Press an item button to be adjusted.
When [MEASURING INSTRUMENT] is pressed:
1) Select the adjustment density pattern.
2) Press [EXECUTE] key.
3) The adjustment pattern is printed out.
4) Enter the adjustment value by the density meter.
5) Press [EXECUTE] key.
Execute  the  manual  correction  of  the  laser  power.  Then  the
adjustment  result  pattern  is  outputted  and  the  data  are  dis-
played.
6) To perform the correction again, press [RETRY] key.
When [VISUAL INSPECTION] is pressed:
1) Select the adjustment density pattern.
2) Press [EXECUTE] key.
3) The adjustment pattern is printed out.
4) Press [4POINT CORRECTION] or [31POINT CORRECTION].
5) Enter an adjustment value.
6) Press [EXECUTE] key.
Execute  the  manual  correction  of  the  laser  power.  Then  the
adjustment  result  pattern  is  outputted  and  the  data  are  dis-
played. 
7) To perform the correction again, press [RETRY] key.
When [DATA] is pressed:
The  display  is  shifted  to  the  manual  adjustment  result  display
screen.
*: Since a special tool is required for measurement, this simulation
 is executed only in the factory.
 
61-13
Purpose
Adjustment
Function (Purpose)
Used  to  clear  the  laser  power  correction
value.
Section
Operation/Procedure
1) Press [EXECUTE] key.
2) Press [YES] key.
Item/Display
Content
Setting 
range
Default 
value
A K_SKEW
Skew Motor Adjustment K
1 - 50(dot)
25
B C_SKEW
Skew Motor Adjustment C
1 - 50(dot)
25
C M_SKEW
Skew Motor Adjustment M
1 - 50(dot)
25
D Y_SKEW
Skew Motor Adjustment Y
1 - 50(dot)
25
E
OFFSET_SKEW_K
Skew Offset value K
1 - 50(dot)
25
F
OFFSET_SKEW_C
Skew Offset value C
1 - 50(dot)
25
G
OFFSET_SKEW_M
Skew Offset value M
1 - 50(dot)
25
H
OFFSET_SKEW_Y
Skew Offset value Y
1 - 50(dot)
25
I MULTI COUNT
Number of print
1 - 999
1
J PAPER
MFT
Tray 
selection
Manual 
paper feed
1 - 5
1
4(CS3)
CS1
Tray 1
2
CS2
Tray 2
3
CS3
Tray 3
4
CS4
Tray 4
5
K DUPLEX
YES
DUPLEX
YES
0 - 1
0
1(NO)
NO
NO
1
Items
Contents
Outline
AUTO 
CORRECTION
Automatic correction
Adjustment by scanner
DATA
Data display screen
Data display when 
executing the automatic 
correction
Items
Contents
Outline
MEASURING 
INSTRUMENT
Density meter correction *
Adjustment with the 
density meter.
VISUAL 
INSPECTION
Visual check adjustment
Adjustment by visual 
check
DATA
Data display screen
Data display during 
execution of the manual 
correction
Reference value reset item
Laser power automatic correction amount (K) 32 data (point)
Laser power automatic correction amount (C) 32 data (point)
Laser power automatic correction amount (M) 32 data (point)
Laser power automatic correction amount (Y) 32 data (point)
Laser power manual correction amount (K) 32 data (point)
Laser power manual correction amount (C) 32 data (point)
Laser power manual correction amount (M) 32 data (point)
Laser power manual correction amount (Y) 32 data (point)
Page of 127
Display

Click on the first or last page to see other MX-6500N / MX-7500N (serv.man20) service manuals if exist.