MX-6240N, MX-7040N (serv.man25). Section 6 Simulation - Updated November 2012 - Sharp Copying Equipment Service Manual (repair manual). Page 126

Read Sharp MX-6240N / MX-7040N (serv.man25) Service Manual online

MX-7040N  SIMULATION  6 – 126
 
63-2
Purpose
Adjustment
Function (Purpose)
Used to perform shading.
Section
Operation/Procedure
• DSPF-installed model
1)
Select [OC SHADING] key or [DSPF SHADING] key, and
press [EXECUTE] key.
Used to perform shading.
When the operation is completed, [EXECUTE] key returns to the
normal display.
 
63-3
Purpose
Adjustment
Function (Purpose)
Used to perform scanner (CCD) color bal-
ance and gamma auto adjustment.
Section
Scanner
Operation/Procedure
1)
Place the SIT chart (UKOG-0280FCZZ or UKOG-0280FCZ1)
on the reference position of the left rear frame side of the doc-
ument table. For the DSPF mode, put the SIT chart backside
up on the DSPF tray.
2)
Select [OC] key or [DSPF] key.
3)
Press [EXECUTE] key.
The scanner (CCD) color balance automatic adjustment is per-
formed.
When the operation is completed, [EXECUTE] key returns to the
normal display.
After completion of the operation, press [RESULT] key, and the
adjustment data are displayed. At that time, the target color of data
display can be selected with [R] [G] [B] key.
OC
ERROR 
CODE
Error code (0, 1 - 14)
7:
Black shading error
8:
Other error
9:
END is not 
asserted. (White 
shading)
10:
END is not 
asserted. (Black 
shading)
11:
END is not 
asserted. (Light 
quantity correction)
12:
END is not 
asserted. (Scan)
13:
Register check 
error (When 
starting/Gain)
14:
Register check 
error (Before light 
quantity correction)
DSPF 
FACE 
WHITE 
LEVEL 1ST
First scan DSPF 
front surface white 
reference level
DSPF 
FACE 
WHITE 
LEVEL 2ND
Second scan DSPF 
front surface white 
reference level
DSPF
ANALOG 
GAIN ODD
Analog gain 
adjustment value 
(odd number)
ANALOG 
GAIN 
EVEN
Analog gain 
adjustment value 
(even number)
DIGITAL 
GAIN ODD
Digital gain 
adjustment value 
(odd number)
DIGITAL 
GAIN 
EVEN
Digital gain 
adjustment value 
(even number)
SMP AVE 
ODD
Reference plate 
sampling average 
value (odd number)
SMP AVE 
EVEN
Reference plate 
sampling average 
value (even number)
TARGET 
VALUE
Target value
BLACK 
LEVEL
Black output level
ERROR 
CODE
Error code (0, 1 - 14)
0:
No error
1:
STAGE1. Loop 
number over
2:
STAGE2. The 
target value is less 
than the specified 
level.
3:
STAGE3. The gain 
set value is 
negative.
4:
END is not 
asserted. (Gain 
adjustment)
5:
(reserve)
6:
STAGE2. 
Underflow
7:
Black shading error
8:
Other error
9:
END is not 
asserted. (White 
shading)
10:
END is not 
asserted. (Black 
shading)
Button
Display 
item
Description
Remarks
DSPF
ERROR 
CODE
Error code (0, 1 - 14)
11:
END is not 
asserted. (Light 
quantity correction)
12:
END is not 
asserted. (Scan)
13:
Register check 
error (When 
starting/Gain)
14:
Register check 
error (Before light 
quantity correction)
DSPF 
BACK 
WHITE 
LEVEL 1ST
First scan DSPF 
back surface white 
reference level
DSPF 
BACK 
WHITE 
LEVEL 2ND
Second scan DSPF 
back surface white 
reference level
Button
Display 
item
Description
Remarks