Read Sharp MX-6240N / MX-7040N (serv.man24) Service Manual online
MX-7040N ADJUSTMENTS AND SETTINGS 5 – 15
4)
Write down the displayed skew level.
Meaning of the skew level value and the adjustment pro-
cedure
cedure
* If "OK" is displayed for all items of SKEW ALL_ROTATE, C,
M, and Y, there is no need to perform the adjustment.
* When "R" is displayed at the head of the value, turn the LSU
skew adjustment screw clockwise.
* When "L" is displayed at the head of the value, turn the LSU
skew adjustment screw counterclockwise.
* The turning amount of the adjustment screw corresponds to
each adjustment value. "ALL_ROTATE" indicates the
number of rotations, and C, M, and Y indicate numbers of
clicks.
number of rotations, and C, M, and Y indicate numbers of
clicks.
The display value is rounded at the decimal point.
* "ALL_ROTATES" shows the number of rotations of
adjustments for all the adjustment screws. "C, M, and Y
(SKEW)" shows the number of adjustment click steps for
each adjustment screw of C, M, and Y.
(SKEW)" shows the number of adjustment click steps for
each adjustment screw of C, M, and Y.
Contents in ( )
MIAN, SUB: Difference from the previous adjustment value of
image registration.
image registration.
Example:
If 105 for this time and 103 for the previous time,
it is displayed as 105.0 (+2.0).
it is displayed as 105.0 (+2.0).
SKEW, ALL_ROTATE: Judgment of the LSU skew adjustment
result. OK or NG.
result. OK or NG.
PHASE: OPC drum phase adjustment value of the previous
time
time
5)
If the display of ALL_ROTATE is NG, turn all the LSU skew
adjustment screws to adjust, and perform the procedures 2) to
4).
adjustment screws to adjust, and perform the procedures 2) to
4).
Repeat the procedures 2) to 5) until the display of
ALL_ROTATE becomes OK. If the display of ALL_ROTATE is
OK, go to the procedure 6).
ALL_ROTATE becomes OK. If the display of ALL_ROTATE is
OK, go to the procedure 6).
For the adjustment, turn the skew adjustment screw with the
front cover open.
front cover open.
Display/Item
Content
Display
NOTE
MAIN F
C
Registration adjustment value main scanning direction
(Cyan laser writing position F side)
(Cyan laser writing position F side)
1.0 - 399.0
Same item with SIM50-20.
* However, the adjustment accuracy is in the unit of
* However, the adjustment accuracy is in the unit of
0.1dot.
M
Registration adjustment value main scanning direction
(Magenta laser writing position F side)
(Magenta laser writing position F side)
1.0 - 399.0
Y
Registration adjustment value main scanning direction
(Yellow laser writing position F side)
(Yellow laser writing position F side)
1.0 - 399.0
MAIN R
C
Registration adjustment value main scanning direction
(Cyan laser writing position R side)
(Cyan laser writing position R side)
1.0 - 399.0
M
Registration adjustment value main scanning direction
(Magenta laser writing position R side)
(Magenta laser writing position R side)
1.0 - 399.0
Y
Registration adjustment value main scanning direction
(Yellow laser writing position R side)
(Yellow laser writing position R side)
1.0 - 399.0
SUB
C
Registration adjustment value sub scanning direction
(Cyan drum
(Cyan drum
Black drum)
1.0 - 399.0
M
Registration adjustment value sub scanning direction
(Magenta drum
(Magenta drum
Black drum)
1.0 - 399.0
Y
Registration adjustment value sub scanning direction
(Yellow drum
(Yellow drum
Black drum)
1.0 - 399.0
SKEW
C
Print skew amount calculation result (Cyan)
L99.9 - R99.9
If the value is positive (+), "L" is displayed at the head of the
value. If negative (–), "R" is displayed.
If the value is in the range of –5.0 - +5.0, "(OK)" is displayed at
the bottom of the value. In the other cases, "(NG)" is displayed.
value. If negative (–), "R" is displayed.
If the value is in the range of –5.0 - +5.0, "(OK)" is displayed at
the bottom of the value. In the other cases, "(NG)" is displayed.
M
Print skew amount calculation result (Magenta)
L99.9 - R99.9
Y
Print skew amount calculation result (Yellow)
L99.9 - R99.9
ALL_ROTATE
Print skew amount calculation result (Overall)
L99.9 - R99.9
If the value is positive (+), "L" is displayed at the head of the
value. If negative (–), "R" is displayed.
If the value is in the range of –3.6 - +3.6, "(OK)" is displayed at
the bottom of the value. In the other cases, "(NG)" is displayed.
value. If negative (–), "R" is displayed.
If the value is in the range of –3.6 - +3.6, "(OK)" is displayed at
the bottom of the value. In the other cases, "(NG)" is displayed.
START
Modulation control start position
(
(
): Previous value
0 - 71
AMP
Modulation control amplitude
(
(
): Previous value
0 - 12.0
Click on the first or last page to see other MX-6240N / MX-7040N (serv.man24) service manuals if exist.