MX-6240N, MX-7040N (serv.man24). Section 5 Adjustments and Settings - Updated November 2012 - Sharp Copying Equipment Service Manual (repair manual). Page 15

Read Sharp MX-6240N / MX-7040N (serv.man24) Service Manual online

MX-7040N  ADJUSTMENTS AND SETTINGS  5 – 15
4)
Write down the displayed skew level.
Meaning of the skew level value and the adjustment pro-
cedure
* If "OK" is displayed for all items of SKEW ALL_ROTATE, C, 
M, and Y, there is no need to perform the adjustment.
* When "R" is displayed at the head of the value, turn the LSU 
skew adjustment screw clockwise.
* When "L" is displayed at the head of the value, turn the LSU 
skew adjustment screw counterclockwise.
* The turning amount of the adjustment screw corresponds to 
each adjustment value. "ALL_ROTATE" indicates the
number of rotations, and C, M, and Y indicate numbers of
clicks.
The display value is rounded at the decimal point.
* "ALL_ROTATES" shows the number of rotations of
adjustments for all the adjustment screws. "C, M, and Y
(SKEW)" shows the number of adjustment click steps for
each adjustment screw of C, M, and Y.
Contents in (    )
MIAN, SUB: Difference from the previous adjustment value of
image registration.
Example: 
If 105 for this time and 103 for the previous time, 
it is displayed as 105.0 (+2.0).
SKEW, ALL_ROTATE: Judgment of the LSU skew adjustment
result. OK or NG.
PHASE: OPC drum phase adjustment value of the previous
time
5)
If the display of ALL_ROTATE is NG, turn all the LSU skew
adjustment screws to adjust, and perform the procedures 2) to
4).
Repeat the procedures 2) to 5) until the display of
ALL_ROTATE becomes OK. If the display of ALL_ROTATE is
OK, go to the procedure 6).
For the adjustment, turn the skew adjustment screw with the
front cover open.
Display/Item
Content
Display
NOTE
MAIN F
C
Registration adjustment value main scanning direction 
(Cyan laser writing position F side)
1.0 - 399.0
Same item with SIM50-20.
* However, the adjustment accuracy is in the unit of 
0.1dot.
M
Registration adjustment value main scanning direction 
(Magenta laser writing position F side)
1.0 - 399.0
Y
Registration adjustment value main scanning direction 
(Yellow laser writing position F side)
1.0 - 399.0
MAIN R
C
Registration adjustment value main scanning direction 
(Cyan laser writing position R side)
1.0 - 399.0
M
Registration adjustment value main scanning direction 
(Magenta laser writing position R side)
1.0 - 399.0
Y
Registration adjustment value main scanning direction 
(Yellow laser writing position R side)
1.0 - 399.0
SUB
C
Registration adjustment value sub scanning direction 
(Cyan drum 
 Black drum)
1.0 - 399.0
M
Registration adjustment value sub scanning direction 
(Magenta drum 
 Black drum)
1.0 - 399.0
Y
Registration adjustment value sub scanning direction 
(Yellow drum 
 Black drum)
1.0 - 399.0
SKEW
C
Print skew amount calculation result (Cyan)
L99.9 - R99.9
If the value is positive (+), "L" is displayed at the head of the 
value. If negative (–), "R" is displayed.
If the value is in the range of –5.0 - +5.0, "(OK)" is displayed at 
the bottom of the value. In the other cases, "(NG)" is displayed.
M
Print skew amount calculation result (Magenta)
L99.9 - R99.9
Y
Print skew amount calculation result (Yellow)
L99.9 - R99.9
ALL_ROTATE
Print skew amount calculation result (Overall)
L99.9 - R99.9
If the value is positive (+), "L" is displayed at the head of the 
value. If negative (–), "R" is displayed.
If the value is in the range of –3.6 - +3.6, "(OK)" is displayed at 
the bottom of the value. In the other cases, "(NG)" is displayed.
START
Modulation control start position
(
): Previous value
0 - 71
AMP
Modulation control amplitude
(
): Previous value
0 - 12.0
Page of 99
Display

Click on the first or last page to see other MX-6240N / MX-7040N (serv.man24) service manuals if exist.