MX-6201N, MX-7001N (serv.man39). FUSING SECTION - Sharp Copying Equipment Service Manual (repair manual). Page 6

Read Sharp MX-6201N / MX-7001N (serv.man39) Service Manual online

MX-7001N  FUSING SECTION  O – 6
4)
Remove the screw (G), and remove the clamp (H). Disconnect
the connector (I). Remove the screws (J), and remove the
mounting plates (K). Remove the screws (L), and remove the
external thermistor main (M) and the external thermistor sub
(N).
c. Upper thermostat main, Upper thermostat sub
1)
Remove the fusing unit.  (Refer to the "(1) Fusing unit".)
2)
Remove the screws (A). Rotate the fusing web unit (B), and
remove it.
* When installing, engage the fusing web unit (B) to the pawl
(C) of the upper cover.
* When installing, be careful to prevent bending the elec-
trodes (D), and check that the electrodes are contacted.
3)
Remove the screws (E), and remove the upper cover (F).
Unit
Parts
1
Fusing unit
e
Upper thermostat main
f
Upper thermostat sub
K
K
J
J
L
L
M
N
1-c
1-d
G
H
I
1-f 1-e
A
A
B
B
C
D
E
F
E
E
Page of 26