MX-6201N, MX-7001N (serv.man20). SELF DIAGNOSIS TROUBLE CODES SECTION - Sharp Copying Equipment Service Manual (repair manual). Page 28

Read Sharp MX-6201N / MX-7001N (serv.man20) Service Manual online

MX-7001N  SELF DIAG AND TROUBLE CODE  8 – 28
 
L4-13
Fusing external heating separation 
trouble
 
L4-30
Controller fan motor trouble
 
L4-31
Paper exit cooling fan F lock
 
L4-32
Power cooling fan 1 lock
 
L4-34
LSU cooling fan trouble
 
L4-35
Fusing exhaust fan lock
 
L4-36
Fusing suction fan lock
 
L4-37
Charger cooling fan lock
 
L4-38
Machine ventilation fan center lock
Trouble content
When the fusing external heating unit is separated, 
the separation sensor status change is not 
detected within the specified time.
Section
PCU
Case 1
Cause
Connector and harness connection trouble
Check and 
remedy
Check connection of the connector and the 
harness.
Case 2
Cause
Separation mechanism trouble, separation motor 
trouble, separation sensor trouble
Check and 
remedy
Check the separation mechanism. Replace the 
separation motor and the separation sensor. 
Case 3
Cause
PCU PWB trouble
Check and 
remedy
Replace the PCU PWB.
Trouble content
1)
The motor lock signal is detected during 
rotation of the controller fan motor.
2)
The motor lock signal is detected during 
rotation of the HDD fan motor.
Section
MFP
Case 1
Cause
Fan motor trouble
Check and 
remedy
Use SIM6-2 to check the operation of the fan 
motor.
Case 2
Cause
Harness connection trouble between the mother 
PWB and the fan motor.
Check and 
remedy
Check the harness and the connector between the 
mother PWB and the fan motor.
Case 3
Cause
Control circuit trouble
Check and 
remedy
Replace the MFPcnt PWB.
Case 4
Cause
Mother PWB trouble.
Check and 
remedy
Replace the mother PWB.
Trouble content
When the paper exit cooling fan F is operated, the 
fan operation signal is not detected within the 
specified time.
Section
PCU
Case 1
Cause
Fan connector disconnection
Check and 
remedy
Check the harness and the connector between the 
PCU PWB and the fan.
Case 2
Cause
Fan does not rotate because of other trouble.
Check and 
remedy
Use SIM6-2 to check that the fan is actually 
rotating.
Trouble content
When the power cooling fan 1 is operated, the fan 
operation signal is not detected within the specified 
time.
Section
PCU
Case 1
Cause
Power cooling fan 1 connector disconnection
Check and 
remedy
Check the harness and the connector between the 
PCU PWB and the fan.
Case 2
Cause
Fan does not rotate because of other trouble
Check and 
remedy
Use SIM6-2 to check that the fan is actually 
rotating.
Trouble content
When the LSU cooling fan is operated, the fan 
operation signal is not detected within the specified 
time.
Section
PCU
Case 1
Cause
Fan connector disconnection
Check and 
remedy
Check the harness and the connector between the 
LSU PWB and the fan.
Case 2
Cause
Fan does not rotate because of other trouble
Check and 
remedy
Use SIM6-2 to check that the fan is actually 
rotating.
If the trouble is not canceled, replace the LSU fan 
and the LSU cnt PWB.
Trouble content
When the fusing exhaust fan is operated, the fan 
operation signal is not detected within the specified 
time.
Section
PCU
Case 1
Cause
Fan connector disconnection
Check and 
remedy
Check the harness and the connector between the 
PCU PWB and the fan.
Case 2
Cause
Fan does not rotate because of other trouble.
Check and 
remedy
Use SIM6-2 to check that the fan is actually 
rotating.
Trouble content
When the fusing suction fan is operated, the fan 
operation signal is not detected within the specified 
time.
Section
PCU
Case 1
Cause
Fan connector disconnection
Check and 
remedy
Check the harness and the connector between the 
PCU PWB and the fan.
Case 2
Cause
Fan does not rotate because of other trouble.
Check and 
remedy
Use SIM6-2 to check that the fan is actually 
rotating.
Trouble content
When the charger cooling fan is operated, the fan 
operation signal is not detected within the specified 
time.
Section
PCU
Case 1
Cause
Fan connector disconnection
Check and 
remedy
Check the harness and the connector between the 
PCU PWB and the fan.
Case 2
Cause
Fan does not rotate because of other trouble.
Check and 
remedy
Use SIM6-2 to check that the fan is actually 
rotating.
Trouble content
When the machine ventilation fan center is 
operated, the fan operation signal is not detected 
within the specified time.
Section
PCU
Case 1
Cause
Fan connector disconnection
Check and 
remedy
Check the harness and the connector between the 
PCU PWB and the fan.
Case 2
Cause
Fan does not rotate because of other trouble.
Check and 
remedy
Use SIM6-2 to check that the fan is actually 
rotating.