Read Sharp MX-6201N / MX-7001N (serv.man19) Service Manual online
MX-7001N SIMULATION 7 – 18
7
7-1
Purpose
Setting
Function (Purpose) Used to set the operating conditions of
aging.
Section
Other
Operation/Procedure
1)
1)
Select a target to be set with the touch panel key.
2)
Press [EXECUTE] key.
The machine is rebooted in the aging mode.
Afterward, the operation mode is kept until the power is tuned
off or resetting is made.
The machine is rebooted in the aging mode.
Afterward, the operation mode is kept until the power is tuned
off or resetting is made.
7-6
Purpose
Setting
Function (Purpose) Used to set the intermittent aging cycle.
Section
Section
Operation/Procedure
1)
1)
Enter the intermittent aging cycle (unit: sec) with 10-key.
2)
Press [OK] key.
The time entered in procedure 1) is set.
The time entered in procedure 1) is set.
* The interval time can be set in the range of 1 to 900sec.
7-8
Purpose
Operation display
Function (Purpose) Used to display the warm-up time.
Section
Section
Operation/Procedure
Press [EXECUTE] key.
Counting of the warm-up time is started.
* Interruption of counting by pressing [EXECUTE] key is inhibited.
Press [EXECUTE] key.
Counting of the warm-up time is started.
* Interruption of counting by pressing [EXECUTE] key is inhibited.
7-9
Purpose
Operation test/Check
Function (Purpose) Used to set a color in the color mode print-
ing. (Used to check the print in the color
mode.)
mode.)
Section
Operation/Procedure
1)
1)
Select a color for print with the touch panel.
2)
Press [EXECUTE] key.
Printing is started in the selected color.
Printing is started in the selected color.
* If no color is specified, printing is made in all colors.
AGING
Aging operation setup
INTERVAL
Intermittent setup
MISFEED DISABLE
JAM detection enable/disable setup
FUSING DISABLE
Fusing operation enable/disable setup
WARMUP DISABLE
Warm-up disable setup
DV CHECK DISABLE
DV unit detection enable/disable setup
SHADING DISABLE
Shading disable setup
CCD GAIN FREE
CCD gain adjustment free setup
SIMULATION NO.07-01
TEST
AGING TEST SETTING
AGING
INTERVAL
MISFEED DISABLE
FUSING DISABLE
WARMUP DISABLE
DV CHECK DISABLE
1/1
EXECUTE
SHADING DISABLE
CCD GAIN FREE
CLOSE
A :
1
;
CYCLE TIME(SEC)
A:
SIMULATION NO.07-06
INTERVAL AGING CYCLE TIME SETUP
1
1
900
OK
TEST
CLOSE
K
Setup/cancel of black
C
Setup/cancel of cyan
M
Setup/cancel of magenta
Y
Setup/cancel of yellow
SIMULATION NO.07-08
TEST
WARM UP TIME DISPLAY SETTING
CLOSE
EXECUTE
0
SECONDS
CLOSE
K
SIMULATION NO.07-09
TEST
PRINTING COLOR SELECT(COLOR MODE)
C
M
Y
1/1
EXECUTE