Read Sharp MX-5050N / MX-5050V / MX-5070N / MX-5070V / MX-6050N / MX-6050V / MX-6070N / MX-6070V (serv.man87) Technical Bulletin online
Sharp Electronics (UK) Ltd., Document Systems Support
Date:
20
th
Dec 2016
Model:
See below
Ref.:
CCE 1666R
Colour:
White
Page:
1 of 7
TECHNICAL BULLETIN
ROM UPGRADE 5 ~ 6
Caution for firmware upgrade: Make sure to turn off the main power once.
Then turn on the power and upgrade the firmware.
- If the firmware update procedure is executed while MFP is still operating, the operation
panel becomes black after the firmware upgrade and MFP may not be able to start up in
some rare cases
panel becomes black after the firmware upgrade and MFP may not be able to start up in
some rare cases
.
- If upgrading from the version older than 04.01.Z1.00
, you won’t be able to restore original
version.
- If "Google drive" is used with the version older than 04.01.Z1.00, it will no longer be used
after firmware upgrade.
after firmware upgrade.
In that case, go into System Settings > Cloud Connect Settings and enable "Google drive"
for usage.
1. Model Name:
MX-3050N/3550N/4050N/5050N/6050N
MX-3060N/3560N/4060N/3070N/3570N/4070N/5070N/6070N
2. Description:
Upgrade of ICU,ASIC,PCU,SCU,SPF-ROM,E-Manual … (6)
From mid-November 2016
Model
ROM
control No.
BUNDLE
ICU
ASIC
PCU
SCU
SPF
E-Manual
MX-3050N
MX-3550N
MX-4050N
MX-5050N
MX-6050N
MX-3550N
MX-4050N
MX-5050N
MX-6050N
E01
0511K100_
16111601
0511K100 0510Z100 0500Z100 0400Z100
-
0230K100
MX-3060N
MX-3560N
MX-4060N
MX-3560N
MX-4060N
0511Z100_
16111601
0511Z100 0510Z100 0500Z100 0400Z100
-
0230Z100
MX-3070N
MX-3570N
MX-4070N
MX-5070N
MX-6070N
MX-3570N
MX-4070N
MX-5070N
MX-6070N
0400Z100
Item of change :Improvement of inspection program for production process
(Then purpose of version upgrade is to improve productivity. No change in machine
setting since Ver0510Z100/0510K100.)
setting since Ver0510Z100/0510K100.)
Sharp Electronics (UK) Ltd., Document Systems Support
Upgrade of ICU,ASIC,PCU,SCU,SPF-ROM,E-Manual …(5)
From mid-November 2016
Model
ROM
control No.
BUNDLE
ICU
ASIC
PCU
SCU
SPF
E-Manual
MX-3050N
MX-3550N
MX-4050N
MX-5050N
MX-6050N
MX-3550N
MX-4050N
MX-5050N
MX-6050N
E00
0510K100_
16110700
0510K100 0510Z100 0500Z100 0400Z100
-
0230K100
MX-3060N
MX-3560N
MX-4060N
MX-3560N
MX-4060N
0510Z100_
16110700
0510Z100 0510Z100 0500Z100 0400Z100
-
0230Z100
MX-3070N
MX-3570N
MX-4070N
MX-5070N
MX-6070N
MX-3570N
MX-4070N
MX-5070N
MX-6070N
0400Z100
Item of change : See the separate page
ROM Version Combination History Table
No.
Destination
ROM
Control
No.
Model
BUNDLE
ICU
ASIC
PCU
SCU
SPF
FAX
E-Manual
Action
T/R No
(4)
ALL
D01
MX-5070N
MX-6070N
MX-6070N
0401Z100_
16080400
0401Z100
0400Z100
0401Z100
0300Z100
0300Z100
-
0220Z100
2016/8
Mid
CCE-1634
R2
(3)
D00
MX-3050N
MX-3550N
MX-4050N
MX-5050N
MX-6050N
MX-3550N
MX-4050N
MX-5050N
MX-6050N
0400K100_
16061400
0101Z100
0400Z100
0400Z100
0300Z100
-
-
0220K100
2016/6
CCE-1605
MX-3060N
MX-3560N
MX-4060N
MX-3070N
MX-3570N
MX-4070N
MX-5070N
MX-6070N
MX-3560N
MX-4060N
MX-3070N
MX-3570N
MX-4070N
MX-5070N
MX-6070N
0400Z100_
16061400
0101Z100
0400Z100
0400Z100
0300Z100
0300Z100
-
0220Z100
(2)
B01
MX-3060N
MX-3560N
MX-4060N
MX-3070N
MX-3570N
MX-3560N
MX-4060N
MX-3070N
MX-3570N
0201Z100_
16011400
0201Z100
0201Z100
0200Z100
0200Z100
0100Z10a
-
0150Z100
2016/2
Mid
CCE-1515
North
America
MX-3050N
MX-3550N
MX-4050N
MX-3550N
MX-4050N
0201K100_
16011400
0201Z100
0200Z100
0200Z100
0201K100
-
0100Z100
0130K100
Except for
North
America
A01
(1)
ALL
B00
MX-3060N
MX-3560N
MX-4060N
MX-3070N
MX-3570N
MX-3560N
MX-4060N
MX-3070N
MX-3570N
0200Z100_
15121800
0200Z100
0200Z100
0200Z100
0100Z10a
0101Z100
-
0150Z100
2015/12
Mid
CCE-1507
MX-3050N
MX-3550N
MX-4050N
MX-3550N
MX-4050N
0200Z100_
15121800
0200K100
0200Z100
0200Z100
0200Z100
-
0100Z100
0130K100
Sharp Electronics (UK) Ltd., Document Systems Support
【Description】
No.
Item
Description
Model
MX-3050N
MX-3550N
MX-4050N
MX-3550N
MX-4050N
MX-3060N
MX-3560N
MX-4060N
MX-3070N
MX-3570N
MX-4070N
MX-3560N
MX-4060N
MX-3070N
MX-3570N
MX-4070N
MX-5050N
MX-6050N
MX-6050N
MX-5070N
MX-6070N
MX-6070N
1
Main unit
control
Change in specification of account lockout
Authentication failure was managed irrespective of user. The specification
is changed so that authentication failure of each user can be managed.
○
○
○
○
2
Main unit
control
Implementation of Soft SW to print A5 size paper as A5R from Bypass tray.
When this SW is enabled, the A5 size image output from Bypass tray is
automatically output as A5R size.
SIM55-3 SW39 Data 5
0: Disabled (Default)
1: Enabled
*Following setting has to be turned ON to enable this feature:
System Settings > Printer Settings > Condition settings > Enable Detected
Paper Size in Bypass Tray: ON
○
○
○
○
3
Main unit
control
Correction of the following issues which may be caused at startup of the
machine.
*E7-90 trouble
*Indication of Toner Quantity [0%]
○
○
○
○
4
Main unit
control
Correction of failure to switch to System Settings
When Address Book DB is corrupted, it cannot be recreated properly that
unable to switch to System Settings.
○
○
○
○
5
Main unit
control
Correction of operational failure: Following problem occurred when the
MFP was used 25 five days in a row (without turning off the power)
- A message which indicates machine is not available for usage appeared.
- The LCD turned dark.
○
○
○
○
6
Main unit
control
Correction of a problem Downloading E-manual for Asia fails occasionally
○
○
○
○
7
Main unit
control
Correction of slowing down the transmission speed after sending multiple
jobs
○
○
○
○
8
Main unit
control
Eliminating load on SSD
The log data are written many times under the environment where the MFP
switches to power save mode and recover from power save mode
frequently. The transition time from 1W power save mode -> silent recovery
-
> power save mode has been changed from “1 min.” to “15 min.” to
decrease the writing of log data to reduce load on SSD.
○
○
○
○
9
Main unit
control
Correction of failure to notify IPP authentication error to a client
○
○
○
○
10
Main unit
control
Correction of failure to change the current status of Machine Identification
from “Input Tray Empty”
from “Input Tray Empty”
○
○
○
○
11
Main unit
control
Correction of failure to recover from power save mode
○
○
○
○
12
Main unit
control
Correction of failure to reflect the name of the registered paper type in the
Tray Settings
○
○
○
○
13
Main unit
control
Correction of failure to execute “Save User Count”
○
○
○
○
14
Main unit
control
Correction of failure which tapping of “Contacts/Group Address” icon on
Home screen rejected, displaying an error message “This function cannot
be selected.”.
Home screen rejected, displaying an error message “This function cannot
be selected.”.
○
○
○
○
○=applied
Sharp Electronics (UK) Ltd., Document Systems Support
No.
Item
Description
Model
MX-3050N
MX-3550N
MX-4050N
MX-3550N
MX-4050N
MX-3060N
MX-3560N
MX-4060N
MX-3070N
MX-3570N
MX-4070N
MX-3560N
MX-4060N
MX-3070N
MX-3570N
MX-4070N
MX-5050N
MX-6050N
MX-6050N
MX-5070N
MX-6070N
MX-6070N
15
Main unit
control
Correction of E7-03 error or failure to start-up MFP。
○
○
○
○
16
Main unit
control
Correction of high temperature offset on B4/B5 size paper with Plain Paper
Weight Setting 90 g/m² - 105g g/m²(23+~28lbs
’)
Plain Paper Weight Settings
System Settings > Common Settings > Device Control
NA
NA
○
○
17
Main unit
control
Change of judgement conditions to execute auto cleaning for main charger
The purpose of this change is to remedy uneven charge under low humidity
environment
NA
NA
○
○
18
Main unit
control
Correction of L4-19
The error due to toner waste buildup caused by the failure to detect waste
toner box full has been fixed.
○
○
○
○
19
Main unit
control
Change of heater lamp control
This is to adjust to the fluorescent which flickers during fluctuation of
voltage.
○
○
○
○
20
Main unit
control
Remedy of overtoning and toner dispersion due to replenishment of excess
amount of toner
○
○
○
○
21
Main unit
control
Correction of C1-01/03/05/07 trouble during MC cleaning under HH
environment
NA
NA
○
○
22
Main unit
control
Correction of false detection of F2-22 (Discharge lamp trouble (K))
The trouble may occur while the job in monochrome mode (which tends to
trigger the execution of process control for BK) is mainly running.
NA
NA
○
○
23
Main unit
control
Correction of F2-65 trouble
This trouble may occur if the MFP is runs out of toner during continuous
run, failing to replenish the toner properly.
NA
NA
○
○
24
Main unit
control
Correction of failure to recognize original
The problem may occur if an OC cover is opened and closed too quickly
after placing an original on the table, failing to detect original size.
○
○
○
○
25
Main unit
control
Correction of machine lockup
The lockup may occur while scanning non standard size originals (with 235
mm in width) on RSPF, displaying “Originals are being read”.
mm in width) on RSPF, displaying “Originals are being read”.
○
○
○
○
26
Printer
Correction of the error (Size illegal) caused when printing out the long size
paper if the setting is the printer driver preferred setting.
○
○
○
○
27
Printer
Printer using AirPrint cannot be registered with Mac OS 10.10. This has
been supported.
○
○
○
○
28
Printer
Correction of the error (Large-volume of pages is printed as text data)
caused when printing the specific EPS file.
○
○
○
○
29
Printer
Correction of the problem that the machine does not output the data with
"Rendering" displayed in Job Status screen when printing the specific data.
○
○
○
○
30
Printer
Correction of failure to print on Index paper properly
When Index paper setting is turned on and Short Edge Duplex is set, the
papers are bound on long edge.
○
○
○
○
31
Printer
Correction of failure to register Print release
If multiple jobs for print release are registered all at once, the jobs may not
be registered on Print release job screen.
○
○
○
○
32
Printer
Correction of failure to perform Cloud Print properly
When 2-Sided Tablet (Booklet) and 8 up are set for Cloud Print, the job may
not be performed properly.
○
○
○
○
○=applied