Read Sharp MX-5050N / MX-5050V / MX-5070N / MX-5070V / MX-6050N / MX-6050V / MX-6070N / MX-6070V (serv.man33) Technical Bulletin online
[CR4] Procedure to install CL roller unit to Fusing unit
Remove Rear lower PG unit.
*M4 screw x 2pcs
Also remove the
Rear lower PG unit removed
Remove Stay (sheet metal).
*M4 screw x 2pcs
M3 Step screw x 1pc
M4 screw
M3 Step
M4 screw
Stay (sheet metal) which
should be removed
Stay (sheet metal) removed.
*Install CL system to the position of the
removed stay.
Cover (resin) which
should be removed.
Step1
Step2
With no Lower separate plate
UN;
With Lower separate plate;