Read Sharp MX-5050N / MX-5050V / MX-5070N / MX-5070V / MX-6050N / MX-6050V / MX-6070N / MX-6070V (serv.man2) Handy Guide online
SHARP
MAINTENANCE
19
MX-30
x
0N
MX-35
x
0N
MX-40x0N
MX-5070N
MX-6070N
MX-6070N
Every
250K
Every
300K
Every
300K
FUSING SECTION:
Replace Fusing Belt unit:-
x
Fusing Belt Unit (MX-607FB).
x
x
Fusing Belt Unit (MX-608FB).
Note: MX-607FB cannot be used on MX-5070N/6070N series
Replace Pressure Roller Kit (MX-607LH):-
Pressure Roller
Apply UKOG-0235FCZZ grease to the shaft section of the Pressure
Roller.
Roller.
Check/Clean both Upper and Lower Thermistors.
Sim 24-04
Clear Fusing Belt Counters.
Clear Fusing Roller Counters.
Clear Press Roller Counters.
Clear Separation Pawl Counters.
Clear Separation Plate Counters.
Clear Fusing Unit Counter.
TRANSFER SECTION:
Replace Primary (Image) Transfer Belt Kit (MX-607B1):-
Primary Transfer Belt
Replace Primary Transfer Cleaning Blade Kit (MX-607TL):-
Primary Transfer Blade.
Cleaning Roller
Cleaning Roller
Apply Yellow Toner [CKOG-0345DS51] to Primary Transfer Belt
Replace Secondary Transfer Roller Kit (MX-607B2):-
Secondary Transfer Roller Unit.
Clean ID & Registration Sensors.
Sim 24-04
Clear TC1 Belt Counters.
Clear Trans Blade Counters.
Clear TC1 Belt Unit Counter.
Clear TC2 Roller Counters.
Clear TC2 Roller Unit Counter.
Sim 50-22
Drum Position & Registration Adjustment - select ALL.
Every
300K
Every
300K
Every
300K
FILTER SECTION:
Replace Ozone Filter Kit (MX-607FL):-
Ozone Filter
Sim 24-04
Clear Ozone Filter Counter.