31
Document Solutions After Sales Service
Hard Drive Recovery Procedure
7. After reading is completed, the firmware update (writing) will commence.
Note: The abbreviated name/location of the firmware that is being updated will appear in the upper right
corner.
corner.
8. If the firmware upgrade completes successfully, RESULT OK will be displayed.
Result NG: Update Failed.
Not Update: Update process was not performed. The firmware may not have been selected or the optional
device (for the firmware) may not be connected or installed.
Not Update: Update process was not performed. The firmware may not have been selected or the optional
device (for the firmware) may not be connected or installed.
9. To exit this mode, press the [BACK] key and turn off the main power.
10. Power on the MFP and import the data from the original HDD unit:‐
• Import the Address Book, Image Send Registration and User Authentication data from the USB
Device (SIM 56‐02) or PC (Device Cloning/Storage Backup).
• Import all Document Filing Data from the USB memory device (SIM 56‐03) or PC, via the MFP
Web interface.
• Install E‐Manual Firmware (Operation Manual) using SIM 49‐03.
Caution: If the original SRAM data could not be backed up (and re‐installed using SIM 56‐02),
execute SIM 67‐70 [
Device (SIM 56‐02) or PC (Device Cloning/Storage Backup).
• Import all Document Filing Data from the USB memory device (SIM 56‐03) or PC, via the MFP
Web interface.
• Install E‐Manual Firmware (Operation Manual) using SIM 49‐03.
Caution: If the original SRAM data could not be backed up (and re‐installed using SIM 56‐02),
execute SIM 67‐70 [
Caution MFP RAM Clear
].
HDD replacement is complete.