MX-4100N, MX-4101N, MX-5000N, MX-5001N (serv.man13). Service Manual-Section 5-Adjustments - Sharp Copying Equipment Service Manual (repair manual). Page 15

Read Sharp MX-4100N / MX-4101N / MX-5000N / MX-5001N (serv.man13) Service Manual online

MX-4101N  ADJUSTMENTS  5 – 15
 
ADJ 7
OPC drum phase adjustment
This adjustment is needed in the following situations:
* When the color shift occurs.
* When the photoconductor drum is replaced.
* When the OPC drum is removed from the main unit.
* When the OPC drum drive section is disassembled.
* When the OPC drum drive unit is replaced.
* U2 trouble has occurred.
* When the PCU MAIN PWB is replaced.
* When EEPROM on the PCU MAIN PWB is replaced.
* When the color image sensor (image registration sensor F) is
replaced.
* When the color image sensor (image registration sensor R) is
replaced.
 
7-A
OPC drum phase adjustment 
(Auto adjustment)
1)
Enter SIM50-22 mode.
2)
Press [ALL] key.
(The machine enters the OPC drum phase adjustment mode/
image registration adjustment (auto adjustment) mode, and
both adjustments are executed simultaneously in this mode.)
The OPC drum phase adjustment and the image registration
adjustment can be individually executed by [REGIST] button
and [DRUM POS] button. Since, however, the image registra-
tion adjustment must be executed when the OPC drum phase
adjustment is completed, both adjustment are executed in this
adjustment simultaneously.
3)
Press [EXECUTE] key.
The OPC drum phase adjustment and the image registration
adjustment are executed automatically.
* After completion of the adjustment, the drum motor stops and
[EXECUTE] button returns to the normal display and the adjust-
ment result is displayed. 
* In case of an error, "ERROR" is displayed with the details.
㪘㪹㫅㫆㫉㫄㪸㫃㩷㪼㫅㪻
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
7(67
$872$'-8670(172)5(*,675$7,21 '580326,7,21
35(66>(&(;87(@7267$57
(55257211(5(037<
(;(&87(
EXECUTE
㪘㪻㫁㫌㫊㫋㫄㪼㫅㫋㩷㪺㫆㫄㫇㫃㪼㫋㪼㪻
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
7(67
$872$'-8670(172)5(*,675$7,21 '580326,7,21
12:(;(&87,1*
(;(&87(
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
7(67
$872$'-8670(172)5(*,675$7,21 '580326,7,21
0$,1)0$,1568%6.(:
&/1*
0/1*
</1*
(;(&87(
'580326
5(*,67
$//
MAIN, SUB
Image regist adjustment value is displayed.
( ) is the difference from the previous adjustment value.
Example: This time 105.0, previous time 103.0 : 105.0 (+2)
PHASE
OPC drum phase adjustment value is displayed.
( ) is the previous adjustment value.
Example: This time 90
°, previous time 45° : 3 (2)
Page of 105
Display

Click on the first or last page to see other MX-4100N / MX-4101N / MX-5000N / MX-5001N (serv.man13) service manuals if exist.