Read Sharp MX-4100N / MX-4101N / MX-5000N / MX-5001N (serv.man13) Service Manual online
MX-4101N ADJUSTMENTS 5 – 10
ADJ 5
Image density sensor (image
registration sensor) adjustment
registration sensor) adjustment
There are some parts variations in the image density sensor sec-
tion. Therefore, the absolute detection level differs in each
machine. To correct this, calibration is executed.
This adjustment is needed in the following situations:
* When the image density sensor (image registration sensor) is
tion. Therefore, the absolute detection level differs in each
machine. To correct this, calibration is executed.
This adjustment is needed in the following situations:
* When the image density sensor (image registration sensor) is
replaced.
* U2 trouble has occurred.
* The PCU PWB has been replaced.
* The EEPROM of the PCU PWB has been replaced.
The targets of the adjustment are the color image density sensor
(image registration sensor F) and the black image density sensor
(image registration sensor R). There are following adjustment
methods.
* Color image density sensor (image registration sensor F) calibra-
* The PCU PWB has been replaced.
* The EEPROM of the PCU PWB has been replaced.
The targets of the adjustment are the color image density sensor
(image registration sensor F) and the black image density sensor
(image registration sensor R). There are following adjustment
methods.
* Color image density sensor (image registration sensor F) calibra-
tion SIM44-13
* Black image density sensor (image registration sensor R) cali-
bration SIM44-2
NOTE: The color image density sensor detects color image density
and image registration on front frame side, the black image
density sensor detects black image density and image reg-
istration on rear frame side. That is, two functions is
assigned to each one sensor.
Before executing this adjustment, check to confirm the fol-
lowing items.
density sensor detects black image density and image reg-
istration on rear frame side. That is, two functions is
assigned to each one sensor.
Before executing this adjustment, check to confirm the fol-
lowing items.
* Check to confirm that the color image density sensor (image reg-
istration sensor F) and the black image density sensor (image
registration sensor R) are clean.
registration sensor R) are clean.
* Check to confirm that the image density sensor calibration plate
is clean.
* Check to confirm that the transfer belt is clean and free from
scratches.
5-A
Color image density sensor (image
registration sensor F) calibration
registration sensor F) calibration
1)
Open the front cabinet of the main unit, and remove the waste
toner box.
toner box.
2)
Remove the primary transfer unit fixing screw.
3)
Turn to the transfer belt tension release cam and release the
primary transfer belt tension.
primary transfer belt tension.
CAUTION: When the transfer belt tension of the primary transfer
unit is released manually, turn on the power again after
completion of the work. This procedure initializes the
transfer roller to return it to the home position.
completion of the work. This procedure initializes the
transfer roller to return it to the home position.
4)
Open the right cover unit (secondary transfer unit section).
AB
TC2 CLEAN LOW SPD
Secondary
transport
cleaning bias
reference value
transport
cleaning bias
reference value
In low speed print
0 - 255
0
0V - –1500V
0V
AC
TC2 CLEAN MIDDLE SPD
In middle speed print
0
0V
AD
TC2 CLEAN CLEANING
Cleaning
85
–500V
AE
VPTC LOW SPEED CL
PTC applied
voltage control
(AC constant
voltage setting)
voltage control
(AC constant
voltage setting)
Color
Low speed
0 - 255
100
0 - (1.94) - 4.01KV
2.47KV
AF
VPTC MIDDLE SPEED CL
Middle speed
100
2.47KV
AG
VPTC LOW SPEED BK
Black/White
Low speed
100
2.47KV
AH
VPTC MIDDLE SPEED BK
Middle speed
100
2.47KV
AI
FPTC LOW SPEED CL
PTC applied
voltage control
(frequency
setting value)
voltage control
(frequency
setting value)
Color
Low speed
1 - 255
192
0.5KHz - 1.5KHz
0.5KHz
AJ
FPTC MIDDLE SPEED CL
Middle speed
192
0.5KHz
AK
FPTC LOW SPEED BK
Black/White
Low speed
192
0.5KHz
AL
FPTC MIDDLE SPEED BK
Middle speed
136
0.7KHz
AM
DCPTC LOW SPEED CL
PTC applied
voltage control
(DC constant
voltage setting
value)
voltage control
(DC constant
voltage setting
value)
Color
Low speed
0 - 255
93
0 - (0.68) - 2.14KV
–1.0KV
AN
DCPTC MIDDLE SPEED CL
Middle speed
149
–1.4KV
AO
DCPTC LOW SPEED BK
Black/White
Low speed
149
–1.4KV
AP
DCPTC MIDDLE SPEED BK
Middle speed
149
–1.4KV
AQ
PTC_HT
PTC heater
operating
environment
setting
operating
environment
setting
0: OFF
1-6: Environment conditions
(TC environment table 6 steps)
0 - 6
1
Always ON
AR
HT_DUTY
Setting of the
supply power in
PTC heater
constant
operation (Duty
ratio setting)
supply power in
PTC heater
constant
operation (Duty
ratio setting)
0: OFF
10: Lighting-up fully
(10 steps)
0 - 10
5
0% - 100%
50%
Item/Display
Content
Setting
range
Default
value
Actual output
setting range
Default value
of actual
output value
UNLOCK
Click on the first or last page to see other MX-4100N / MX-4101N / MX-5000N / MX-5001N (serv.man13) service manuals if exist.