MAINTENANCE
SHARP
Page 18
/75
MX-2630N Handy Guide NOV’17
Sharp Office Solutions Group
MX-2630N
Every
250K
FUSING SECTION (Cont’d):
Sim 24-04
Clear Fusing Belt Counters.
Clear Fusing Roller Counters.
Clear Press Roller Counters.
Clear Separation Pawl Counters.
Clear Separation Plate Counters.
Clear Fusing Unit Counter.
TRANSFER SECTION:
Replace Primary (Image) Transfer Belt Kit (MX-607B1):-
•
Primary Transfer Belt
Replace Primary Transfer Cleaning Blade Kit (MX-607TL):-
• Primary Transfer Blade.
• Cleaning Roller
• Cleaning Roller
Apply Yellow Toner [CKOG-0345DS51] to Primary Transfer Belt
Replace Secondary Transfer Roller Kit (MX-607B2):-
•
Secondary Transfer Roller Unit.
Clean ID & Registration Sensors.
Sim 24-04
Clear TC1 Belt Counters.
Clear Trans Blade Counters.
Clear TC1 Belt Unit Counter.
Clear TC2 Roller Counters.
Clear TC2 Roller Unit Counter.
Sim 50-22
Drum Position & Registration Adjustment - select ALL.
Every
300K
FILTER SECTION:
Replace Ozone Filter Kit (MX-607FL):-
•
Ozone Filter
Sim 24-04
Clear Ozone Filter Counter.
INNER FINISHER [MX-FN27 N]
Clean inlet paper transport rollers.
Clean paper exit paddle.
Clean paper guides and tray.
Check/Replace Staple Unit every 200K staples
[0CW4H560160//]
Check/Replace Staple Less Staple Unit assembly every 20K staples
[0CW4M511130//]
1K FINISHER [MX-FN29]:
Clean paper transport rollers.
Clean all sensors.
Check/Replace Staple Unit every 500K staples
[0JEAJ011030//]
Check/Replace Saddle Staple Unit 200K staples
[0JEAJ011031//]