Read Sharp MX-2630 (serv.man6) Handy Guide online
MAINTENANCE
SHARP
Page 16
/75
MX-2630N Handy Guide NOV’17
Sharp Office Solutions Group
MX-2630N
PROCESS SECTION – COLOUR:
(Colour maintenance counter has reached the specified life).
(Colour maintenance counter has reached the specified life).
Every
150K
Every
300K
Replace Cyan, Magenta & Yellow OPC Drum: (MX-60GRSA x 3)
Replace Cyan, Magenta & Yellow Main Charge Kits:-
• Main Charge Unit & Cleaning Blade (MX-407MK x 3)
x
Replace C, M, Y Developer (MX-60GVSA).
Clean LSU Dust Proof Glass (CMYK)
Sim 24-04
Clear Drum CTRG C, M, Y (Colour) Counters.
Clear Main Charger C, M, Y (Colour) Counters.
(MC Cleaner Counter is also cleared automatically)
Clear Drum Blade C, M, Y (Colour) Counters.
Clear Maintenance [Colour] Counter.
Sim 24-05
Clear Developer C, M, Y (Colour) Counters.
x
Remove ALL toner cartridges, prior to executing Sim 25-02.
x
Sim 25-02
Toner Concentration Adjustment - Select C, M, Y.
Note:
If ALL developer is replaced at the same time, select CMYK. When
Sim 25-02 is executed, the Developer Counter (Sim 24-05) is also
cleared automatically.
Sim 25-02 is executed, the Developer Counter (Sim 24-05) is also
cleared automatically.
x
Sim 44-27
Clear Half Tone Process Correction.
Every
180K
Every
360K
PROCESS SECTION -MONOCHROME:
(Total / K maintenance counter has reached the specified life).
(Total / K maintenance counter has reached the specified life).
Replace Black OPC Drum (MX-60GRSA).
Replace Black Main Charge Kit:-
• Main Charge Unit & Cleaning Blade (MX-407MK)
x
Replace Black Developer (MX-60GVBA).
Clean LSU Dust Proof Glass (CMYK)
Sim 24-04
Clear Drum CTRG K (Black) Counter.
Clear Main Charger K (Black) Counter.
(MC Cleaner Counter is also cleared automatically)
Clear Drum Blade K (Black) Counter.
Clear Maintenance [ALL] Counter.
x
Sim 24-05
Clear Developer K (Black) Counter.
x
Remove ALL toner cartridges, prior to executing Sim 25-02.
x
Sim 25-02
Toner Concentration Auto Adjustment - Select K.
Note:
If ALL developer is replaced at the same time, select CMYK. When
Sim 25-02 is executed, the Developer Counter (Sim 24-05) is also
cleared automatically.
Sim 25-02 is executed, the Developer Counter (Sim 24-05) is also
cleared automatically.
Click on the first or last page to see other MX-2630 (serv.man6) service manuals if exist.