MAINTENANCE 
SHARP  
 
Page 16
/75
 
MX-2630N Handy Guide NOV’17 
Sharp Office Solutions Group
 
 
MX-2630N 
PROCESS SECTION – COLOUR: 
(Colour maintenance counter has reached the specified life). 
Every 
150K 
Every 
300K 
 
 
 
 
 
Replace Cyan, Magenta & Yellow OPC Drum: (MX-60GRSA x 3)  
 
 
Replace Cyan, Magenta & Yellow Main Charge Kits:- 
 
 
•  Main Charge Unit & Cleaning Blade (MX-407MK x 3) 
 
Replace C, M, Y Developer (MX-60GVSA). 
 
 
Clean LSU Dust Proof Glass (CMYK) 
 
 
Sim 24-04  
Clear Drum CTRG C, M, Y (Colour) Counters. 
 
 
 
 
Clear Main Charger C, M, Y (Colour) Counters. 
 
 
(MC Cleaner Counter is also cleared automatically) 
 
 
 
 
Clear Drum Blade C, M, Y (Colour) Counters. 
 
 
 
 
Clear Maintenance [Colour] Counter. 
 
 
Sim 24-05  
Clear Developer C, M, Y (Colour) Counters. 
 
Remove ALL toner cartridges, prior to executing Sim 25-02.
 
 
Sim 25-02  
Toner Concentration Adjustment - Select C, M, Y. 
 
 
Note:   
If ALL developer is replaced at the same time, select CMYK. When 
Sim 25-02 is executed, the Developer Counter (Sim 24-05) is also 
cleared automatically. 
 
Sim 44-27  
Clear Half Tone Process Correction. 
 
 
Every 
180K 
Every 
360K 
PROCESS SECTION -MONOCHROME: 
(Total / K maintenance counter has reached the specified life). 
 
 
 
 
 
Replace Black OPC Drum (MX-60GRSA). 
 
 
Replace Black Main Charge Kit:- 
 
 
•  Main Charge Unit & Cleaning Blade (MX-407MK) 
 
Replace Black Developer (MX-60GVBA). 
 
 
Clean LSU Dust Proof Glass (CMYK) 
 
 
Sim 24-04  
Clear Drum CTRG K (Black) Counter. 
 
 
 
 
Clear Main Charger K (Black) Counter. 
 
 
(MC Cleaner Counter is also cleared automatically) 
 
 
 
 
Clear Drum Blade K (Black) Counter. 
 
 
 
 
Clear Maintenance [ALL] Counter. 
 
Sim 24-05  
Clear Developer K (Black) Counter. 
 
Remove ALL toner cartridges, prior to executing Sim 25-02.
 
 
Sim 25-02  
Toner Concentration Auto Adjustment - Select K. 
 
 
Note:   
If ALL developer is replaced at the same time, select CMYK. When 
Sim 25-02 is executed, the Developer Counter (Sim 24-05) is also 
cleared automatically. 
 
 