Read Sharp MX-2610N / MX-3110N / MX-3610N (serv.man191) Technical Bulletin online
Sharp Electronics (UK) Ltd., Technical Services Group
CCE-965
- MX-2610N/3110N/3111U
Fusing Temperature Setup Point (Group C)
Fusing Temperature Setup Point (Group C)
SW-A
SW-B
Ite
m
s
Setup Details
Set within the range for each
item.
Do not set outside this range
item.
Do not set outside this range
Set within the range for each
item.
Do not set outside this range
item.
Do not set outside this range
(1) (2)
Fac
tor
y def
aul
t
val
ue
(3) (4)
(1) (2)
Fac
tor
y def
aul
t
val
ue
(3) (4)
MX
-2610N
/3110N
/3111U
(G
roup C
)
S
im
43
-1
A Ready standby TH_UM set value
100 105 110 115 120 115 120 125 130 135
B Ready standby TH_LM set value
95 100 105 110 115 105 110 115 120 125
C Ready standby TH_US set value
145 150 155 160 165 155 160 165 170 175
D Black-White plain paper TH_UM set value
125 130 135 140 145 125 130 135 140 145
E Black-White plain paper TH_LM set value
110 110 115 120 120 115 120 125 125 125
F Black-White plain paper TH_US set value
145 150 155 160 165 150 155 160 165 170
G Color plain paper TH_UM set value
125 130 135 140 145 135 140 145 150 155
H Color plain paper TH_LM set value
110 110 115 120 120 115 120 125 125 125
I Color plain paper TH_US set value
145 150 155 160 165 155 160 165 170 175
Y Preheating TH_UM set value
90
95 100 105 110 90
95 100 105 110
Z Preheating TH_US set value
120 125 130 135 140 120 125 130 135 140
AB Preheating TH_LM set value
90
90
90
95 100 90
90
90
95 100
AF TH_UM set value when Warm-Up at 120°C or below
135 140 145 150 155 140 145 150 155 160
AG TH_LM set value when Warm-Up at 120°C or below
100 100 105 110 110 105 110 115 115 115
AH TH_US set value when Warm-Up at 120°C or below
140 145 150 155 160 145 150 155 160 165
AJ TH_UM set value when Warm-Up at 120°C or above
135 140 145 150 155 140 145 150 155 160
AK TH_LM set value when Warm-Up at 120°C or above
100 100 105 110 110 105 110 115 115 115
AL TH_US set value when Warm-Up at 120°C or above
140 145 150 155 160 145 150 155 160 165
AP
Job enable TH_UM temperature when Warm-Up at
alpha °C or above
135 140 145 150 155 140 145 150 155 160
AR
Job enable TH_UM temperature when Warm-Up at
alpha °C or below
135 140 145 150 155 140 145 150 155 160
AT
Job enable temperature (B/W) when the upper roller
temperature is lower than alpha °C
135 140 145 150 155 140 145 150 155 160
S
im
43
-4
A Black-White plain paper duplex TH_UM set value
125 130 135 140 145 125 130 135 140 145
B Black-White plain paper duplex TH_LM set value
110 110 115 120 120 115 120 125 125 125
C Black-White plain paper duplex TH_US set value
145 150 155 160 165 150 155 160 165 170
E Color plain paper duplex TH_UM set value
125 130 135 140 145 135 140 145 150 155
F Color plain paper duplex TH_LM set value
110 110 115 120 120 115 120 125 125 125
G Color plain paper duplex TH_US set value
145 150 155 160 165 155 160 165 170 175
Lower setup Higher
Lower setup Higher
Click on the first or last page to see other MX-2610N / MX-3110N / MX-3610N (serv.man191) service manuals if exist.