MX-2610N, MX-3110N, MX-3610N (serv.man191). FUSING TEMPERATURE SETUP POINTS AS ACTION FOR (PLAIN) PAPER JAM, ETC. DUE TO CURLED PAPER - Sharp Copying Equipment Technical Bulletin (repair manual). Page 3

Read Sharp MX-2610N / MX-3110N / MX-3610N (serv.man191) Technical Bulletin online

 
 
 
Sharp Electronics (UK) Ltd., Technical Services Group
 
CCE-965 
 
 
 - MX-2610N/3110N/3111U  
  Fusing Temperature Setup Point (Group C) 
SW-A 
SW-B 
 
 
Ite
m
Setup Details 
Set within the range for each 
item. 
Do not set outside this range 
 
 
 
Set within the range for each 
item. 
Do not set outside this range 
 
 
 
(1)  (2) 
Fac
tor
y def
aul
val
ue
 
(3)  (4) 
(1)  (2) 
Fac
tor
y def
aul
val
ue
 
(3)  (4) 
MX
-2610N
/3110N
/3111U
 (G
roup C
S
im
43
-1
 
A  Ready standby TH_UM set value 
100  105  110  115  120  115  120  125  130  135 
B  Ready standby TH_LM set value 
95  100  105  110  115  105  110  115  120  125 
C  Ready standby TH_US set value 
145  150  155  160  165  155  160  165  170  175 
D  Black-White plain paper TH_UM set value 
125  130  135  140  145  125  130  135  140  145 
E  Black-White plain paper TH_LM set value 
110  110  115  120  120  115  120  125  125  125 
F  Black-White plain paper TH_US set value 
145  150  155  160  165  150  155  160  165  170 
G  Color plain paper TH_UM set value 
125  130  135  140  145  135  140  145  150  155 
H  Color plain paper TH_LM set value 
110  110  115  120  120  115  120  125  125  125 
I  Color plain paper TH_US set value 
145  150  155  160  165  155  160  165  170  175 
Y  Preheating TH_UM set value 
90 
95  100  105  110  90 
95  100  105  110 
Z  Preheating TH_US set value 
120  125  130  135  140  120  125  130  135  140 
AB  Preheating TH_LM set value 
90 
90 
90 
95  100  90 
90 
90 
95  100 
AF  TH_UM set value when Warm-Up at 120°C or below 
135  140  145  150  155  140  145  150  155  160 
AG  TH_LM set value when Warm-Up at 120°C or below 
100  100  105  110  110  105  110  115  115  115 
AH  TH_US set value when Warm-Up at 120°C or below 
140  145  150  155  160  145  150  155  160  165 
AJ  TH_UM set value when Warm-Up at 120°C or above 
135  140  145  150  155  140  145  150  155  160 
AK  TH_LM set value when Warm-Up at 120°C or above 
100  100  105  110  110  105  110  115  115  115 
AL  TH_US set value when Warm-Up at 120°C or above 
140  145  150  155  160  145  150  155  160  165 
AP 
Job enable TH_UM temperature when Warm-Up at 
alpha °C or above 
135  140  145  150  155  140  145  150  155  160 
AR 
Job enable TH_UM temperature when Warm-Up at 
alpha °C or below 
135  140  145  150  155  140  145  150  155  160 
AT 
Job enable temperature (B/W) when the upper roller 
temperature is lower than alpha °C 
135  140  145  150  155  140  145  150  155  160 
S
im
43
-4
 
A  Black-White plain paper duplex TH_UM set value 
125  130  135  140  145  125  130  135  140  145 
B  Black-White plain paper duplex TH_LM set value 
110  110  115  120  120  115  120  125  125  125 
C  Black-White plain paper duplex TH_US set value 
145  150  155  160  165  150  155  160  165  170 
E  Color plain paper duplex TH_UM set value 
125  130  135  140  145  135  140  145  150  155 
F  Color plain paper duplex TH_LM set value 
110  110  115  120  120  115  120  125  125  125 
G  Color plain paper duplex TH_US set value 
145  150  155  160  165  155  160  165  170  175 
 
Lower setup  Higher 
 
 
Lower setup  Higher 
 
 