Read Sharp MX-2610N / MX-3110N / MX-3610N (serv.man191) Technical Bulletin online

 
 
 
Sharp Electronics (UK) Ltd., Technical Services Group
 
CCE-965 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1. Model Name: 
MX-2310U/3111U, MX-2610N/3110N/3610N 
 
2. General:   
On some paper type and under some environment of use (high in humidity), the paper  
 
 
 
may get jammed, etc. at the fusing unit or around the delivery section due to curled  
 
 
 
paper. 
 
 
 
When such failure occurred, change the fusing temperature and check how it works. 
 
 
 
Just for your reference, the fusing temeprature setup details for action on defective fusing  
 
 
 
unit is introduced below. However, note that it differs depending on the type of the paper  
 
 
 
used, environment of its use, etc. 
 
 
 
 
[Defective symptoms/setup to be changed]  
 
Defective symptoms  
Setup to be changed 
- If the paper easily gets jammed with too much of  
curl,  
Set with lower temperature. 
Confirm and change in the order of  
[Factory default value → (2) → (1)] . 
 
*See the table attached. 
- If the paper gets jammed with being curled up  
around the upper belt,  
- If the image on the solid area seems to be offsetting  
in high temperature,  
- If the exited paper is felt to be too hot, 
- If the paper is too glossy, 
- If a relatively-thick plain paper (80 to 100g/m
2
) is  
not strong enough in fusibility or there is some  
other failure in fusibility,  
Set with higher temperature. 
Confirm and change in the order of  
[Factory default value → (3) → (4)] . 
 
*See the table attached. 
- It the paper surface condition is bad (rough in its  
smoothness), and its fusibility is not stroug enough  
or there is some other failure in fusibility, 
- It is not defective in fusibility but when it is wished  
to be glossier. 
 
FUSING TEMPERATURE SETUP POINTS AS ACTION 
FOR (PLAIN) PAPER JAM, ETC. DUE TO CURLED PAPER
 
TECHNICAL BULLETIN 
 
Date:  
15
th
 December 2011 
Model:  
MX2610N – MX3110N 
 
 
MX3610N 
Ref.:   
043 
Colour:  
White 
Page:  
1 of 4 
 
 
 
Sharp Electronics (UK) Ltd., Technical Services Group
 
CCE-965 
 
  Note: When to make the setup change, change the entire items on the Setup Details column for Sim43-1  
       and 43-4 as listed on the table below, not individually make a change on the item. 
  [Setup Details] 
 
 - MX-2310U Fusing Temperature Setup Point (Group C) 
SW-A 
SW-B 
 
 
Ite
m
Setup Details 
Set within the range for each 
item. 
Do not set outside this range. 
 
 
 
Set within the range for each 
item. 
Do not set outside this range. 
 
 
 
(1)  (2) 
Fac
tor
y def
aul
val
ue
 
(3)  (4) 
(1)  (2) 
Fac
tor
y d
ef
aul
val
ue
 
(3)  (4) 
MX
-2310U
(G
roup C
S
im
43
-1
 
A  Ready standby TH_UM set value 
100  105  110  115  120  115  120  125  130  135 
B  Ready standby TH_LM set value 
100  100  105  110  115  110  110  115  120  125 
C  Ready standby TH_US set value 
130  135  140  145  150  140  145  150  155  160 
D  Black-White plain paper TH_UM set value 
125  130  135  140  145  135  140  145  150  155 
E  Black-White plain paper TH_LM set value 
110  110  115  120  120  120  120  125  130  130 
F  Black-White plain paper TH_US set value 
130  135  140  145  150  140  145  150  155  160 
G  Color plain paper TH_UM set value 
125  130  135  140  145  135  140  145  150  155 
H  Color plain paper TH_LM set value 
110  110  115  120  120  120  120  125  130  130 
I  Color plain paper TH_US set value 
130  135  140  145  150  140  145  150  155  160 
Y  Preheating TH_UM set value 
90 
95  100  105  110  90 
95  100  105  110 
Z  Preheating TH_US set value 
120  125  130  135  140  120  125  130  135  140 
AB  Preheating TH_LM set value 
80 
85 
90 
95  100  80 
85 
90 
95  100 
AF  TH_UM set value when Warm-Up at 120°C or below 
135  140  145  150  155  135  140  145  150  155 
AG  TH_LM set value when Warm-Up at 120°C or below 
95  100  105  110  115  105  110  115  120  125 
AH  TH_US set value when Warm-Up at 120°C or below 
125  130  135  140  145  135  140  145  150  155 
AJ  TH_UM set value when Warm-Up at 120°C or above 
135  140  145  150  155  135  140  145  150  155 
AK  TH_LM set value when Warm-Up at 120°C or above 
95  100  105  110  115  105  110  115  120  125 
AL  TH_US set value when Warm-Up at 120°C or above 
125  130  135  140  145  135  140  145  150  155 
AP 
Job enable TH_UM temperature when Warm-Up at 
alpha °C or above 
135  140  145  150  155  135  140  145  150  155 
AR 
Job enable TH_UM temperature when Warm-Up at 
alpha °C or below 
135  140  145  150  155  135  140  145  150  155 
AT 
Job enable temperature (B/W) when the upper roller 
temperature is lower than alpha °C 
135  140  145  150  155  135  140  145  150  155 
S
im
43
-4
 
A  Black-White plain paper duplex TH_UM set value 
125  130  135  140  145  135  140  145  150  155 
B  Black-White plain paper duplex TH_LM set value 
110  110  115  120  120  120  120  125  130  130 
C  Black-White plain paper duplex TH_US set value 
130  135  140  145  150  145  150  155  160  165 
E  Color plain paper duplex TH_UM set value 
125  130  135  140  145  140  145  150  155  160 
F  Color plain paper duplex TH_LM set value 
110  110  115  120  120  120  120  125  130  130 
G  Color plain paper duplex TH_US set value 
130  135  140  145  150  145  150  155  160  165 
 
Lower setup  Higher 
 
 
Lower setup  Higher 
 
 
 
 
 
Sharp Electronics (UK) Ltd., Technical Services Group
 
CCE-965 
 
 
 - MX-2610N/3110N/3111U  
  Fusing Temperature Setup Point (Group C) 
SW-A 
SW-B 
 
 
Ite
m
Setup Details 
Set within the range for each 
item. 
Do not set outside this range 
 
 
 
Set within the range for each 
item. 
Do not set outside this range 
 
 
 
(1)  (2) 
Fac
tor
y def
aul
val
ue
 
(3)  (4) 
(1)  (2) 
Fac
tor
y def
aul
val
ue
 
(3)  (4) 
MX
-2610N
/3110N
/3111U
 (G
roup C
S
im
43
-1
 
A  Ready standby TH_UM set value 
100  105  110  115  120  115  120  125  130  135 
B  Ready standby TH_LM set value 
95  100  105  110  115  105  110  115  120  125 
C  Ready standby TH_US set value 
145  150  155  160  165  155  160  165  170  175 
D  Black-White plain paper TH_UM set value 
125  130  135  140  145  125  130  135  140  145 
E  Black-White plain paper TH_LM set value 
110  110  115  120  120  115  120  125  125  125 
F  Black-White plain paper TH_US set value 
145  150  155  160  165  150  155  160  165  170 
G  Color plain paper TH_UM set value 
125  130  135  140  145  135  140  145  150  155 
H  Color plain paper TH_LM set value 
110  110  115  120  120  115  120  125  125  125 
I  Color plain paper TH_US set value 
145  150  155  160  165  155  160  165  170  175 
Y  Preheating TH_UM set value 
90 
95  100  105  110  90 
95  100  105  110 
Z  Preheating TH_US set value 
120  125  130  135  140  120  125  130  135  140 
AB  Preheating TH_LM set value 
90 
90 
90 
95  100  90 
90 
90 
95  100 
AF  TH_UM set value when Warm-Up at 120°C or below 
135  140  145  150  155  140  145  150  155  160 
AG  TH_LM set value when Warm-Up at 120°C or below 
100  100  105  110  110  105  110  115  115  115 
AH  TH_US set value when Warm-Up at 120°C or below 
140  145  150  155  160  145  150  155  160  165 
AJ  TH_UM set value when Warm-Up at 120°C or above 
135  140  145  150  155  140  145  150  155  160 
AK  TH_LM set value when Warm-Up at 120°C or above 
100  100  105  110  110  105  110  115  115  115 
AL  TH_US set value when Warm-Up at 120°C or above 
140  145  150  155  160  145  150  155  160  165 
AP 
Job enable TH_UM temperature when Warm-Up at 
alpha °C or above 
135  140  145  150  155  140  145  150  155  160 
AR 
Job enable TH_UM temperature when Warm-Up at 
alpha °C or below 
135  140  145  150  155  140  145  150  155  160 
AT 
Job enable temperature (B/W) when the upper roller 
temperature is lower than alpha °C 
135  140  145  150  155  140  145  150  155  160 
S
im
43
-4
 
A  Black-White plain paper duplex TH_UM set value 
125  130  135  140  145  125  130  135  140  145 
B  Black-White plain paper duplex TH_LM set value 
110  110  115  120  120  115  120  125  125  125 
C  Black-White plain paper duplex TH_US set value 
145  150  155  160  165  150  155  160  165  170 
E  Color plain paper duplex TH_UM set value 
125  130  135  140  145  135  140  145  150  155 
F  Color plain paper duplex TH_LM set value 
110  110  115  120  120  115  120  125  125  125 
G  Color plain paper duplex TH_US set value 
145  150  155  160  165  155  160  165  170  175 
 
Lower setup  Higher 
 
 
Lower setup  Higher 
 
 
 
 
 
Sharp Electronics (UK) Ltd., Technical Services Group
 
CCE-965 
 
 
 - MX-3610N Fusing Temperature Setup Point (Group C) 
SW-A 
SW-B 
 
 
Ite
m
Setup Details 
Set within the range for each 
item. 
Do not set outside this range 
 
 
 
Set within the range for each 
item. 
Do not set outside this range 
 
 
 
(1)  (2) 
Fac
tor
y def
aul
val
ue
 
(3)  (4) 
(1)  (2) 
Fac
tor
y def
aul
val
ue
 
(3)  (4) 
MX
-3610N
(G
roup C
S
im
43
-1
 
A  Ready standby TH_UM set value 
115  120  125  130  135  130  135  140  145  150 
B  Ready standby TH_LM set value 
95  100  105  110  115  105  110  115  120  125 
C  Ready standby TH_US set value 
150  155  160  165  170  160  165  170  175  180 
D  Black-White plain paper TH_UM set value 
135  140  145  150  155  135  140  145  150  155 
E  Black-White plain paper TH_LM set value 
110  110  115  120  120  115  120  125  125  125 
F  Black-White plain paper TH_US set value 
150  155  160  165  170  150  155  160  165  170 
G  Color plain paper TH_UM set value 
140  145  150  155  160  150  155  160  165  170 
H  Color plain paper TH_LM set value 
110  110  115  120  120  115  120  125  125  125 
I  Color plain paper TH_US set value 
150  155  160  165  170  160  165  170  175  180 
Y  Preheating TH_UM set value 
105  110  115  120  125  105  110  115  120  125 
Z  Preheating TH_US set value 
140  145  150  155  160  140  145  150  155  160 
AB  Preheating TH_LM set value 
90 
90 
90 
95  100  90 
90 
90 
95  100 
AF  TH_UM set value when Warm-Up at 120°C or below 
150  155  160  165  170  155  160  165  170  175 
AG  TH_LM set value when Warm-Up at 120°C or below 
100  100  105  110  110  105  110  115  115  115 
AH  TH_US set value when Warm-Up at 120°C or below 
150  155  160  165  170  155  160  165  170  175 
AJ  TH_UM set value when Warm-Up at 120°C or above 
150  155  160  165  170  155  160  165  170  175 
AK  TH_LM set value when Warm-Up at 120°C or above 
100  100  105  110  110  105  110  115  115  115 
AL  TH_US set value when Warm-Up at 120°C or above 
150  155  160  165  170  155  160  165  170  175 
AP 
Job enable TH_UM temperature when Warm-Up at 
alpha °C or above 
150  155  160  165  170  155  160  165  170  175 
AR 
Job enable TH_UM temperature when Warm-Up at 
alpha °C or below 
150  155  160  165  170  155  160  165  170  175 
AT 
Job enable temperature (B/W) when the upper roller 
temperature is lower than alpha °C 
150  155  160  165  170  155  160  165  170  175 
S
im
43
-4
 
A  Black-White plain paper duplex TH_UM set value 
135  140  145  150  155  135  140  145  150  155 
B  Black-White plain paper duplex TH_LM set value 
100  100  115  120  120  115  120  125  125  125 
C  Black-White plain paper duplex TH_US set value 
150  155  160  165  170  150  155  160  165  170 
E  Color plain paper duplex TH_UM set value 
140  145  150  155  160  150  155  160  165  170 
F  Color plain paper duplex TH_LM set value 
100  100  115  120  120  115  120  125  125  125 
G  Color plain paper duplex TH_US set value 
150  155  160  165  170  160  165  170  175  180 
 
Lower setup  Higher 
 
 
Lower setup  Higher 
 
 
Page of 4
Display

Download Sharp MX-2610N / MX-3110N / MX-3610N (serv.man191) Technical Bulletin

Here you can read online and download Sharp MX-2610N / MX-3110N / MX-3610N (serv.man191) Technical Bulletin in PDF. MX-2610N / MX-3110N / MX-3610N (serv.man191) technical bulletin will guide through the process and help you recover, restore, fix, disassemble and repair Sharp MX-2610N / MX-3110N / MX-3610N (serv.man191) Copying Equipment. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.