MX-RPX1 ADJUSTMENTS 8 – 1
Service Manual
[8] ADJUSTMENTS
1. RSPF magnification ratio adjustment
NOTE: To execute this adjustment, the CCD unit must have been
properly installed. To execute this adjustment, the OC
mode adjustment when copying must have been com-
pleted.
mode adjustment when copying must have been com-
pleted.
1)
Place a scale on the document table as shown in the figure
below, and make a normal copy to make a test chart.
below, and make a normal copy to make a test chart.
2)
Set the test chart on the RSPF, and make a normal copy.
3)
Compare the outputted copy with the test chart. If it is judged
from comparison that an adjustment is required, perform the
following procedures.
from comparison that an adjustment is required, perform the
following procedures.
4)
Execute SIM48-1.
5)
Change the mode to "C: SPF (MAIN)." The current magnifica-
tion ratio correction value is displayed in 2 digits on the display
section.
tion ratio correction value is displayed in 2 digits on the display
section.
6)
Enter a set value and press [OK] key. The correction value is
saved and a copy is made.
saved and a copy is made.
7)
Change the mode to "E: SPFB (MAIN)." The current magnifi-
cation ratio correction value is displayed in 2 digits on the dis-
play section.
cation ratio correction value is displayed in 2 digits on the dis-
play section.
8)
Enter a set value and press [OK] key. The correction value is
saved and a copy is made.
saved and a copy is made.
9)
Change the mode to "D: SPF (SUB)." The current magnifica-
tion ratio correction value is displayed in 2 digits on the display
section.
tion ratio correction value is displayed in 2 digits on the display
section.
10) Enter a set value and press [OK] key. The correction value is
saved and a copy is made.
11) Change the mode to "F: SPFB (SUB)." The current magnifica-
tion ratio in the back surface sub scanning direction is dis-
played in 2 digits on the display section.
played in 2 digits on the display section.
12) Enter a set value and press [OK] key. The correction value is
saved and a copy is made.
<Adjustment specifications>
2. RSPF document off-center
adjustment
NOTE: To execute this adjustment, the paper off-center must have
been adjusted properly.
1)
Set the test chart for center position adjustment (which is
made by yourself) on the RSPF.
<Adjustment specifications>
Draw a straight line on paper in the scanning direction.
made by yourself) on the RSPF.
<Adjustment specifications>
Draw a straight line on paper in the scanning direction.
2)
Make a normal copy from the manual paper feed tray. Com-
pare the printed copy and the test chart. If an adjustment is
required, perform the following procedures.
pare the printed copy and the test chart. If an adjustment is
required, perform the following procedures.
3)
Execute SIM50-12.
4)
Change the mode to "B: SPF (SIDE1)." The current off-center
adjustment value is displayed in 2 digits on the display section.
adjustment value is displayed in 2 digits on the display section.
5)
Enter a set value and press [START] key. The correction value
is saved and a copy is made.
is saved and a copy is made.
6)
Change the mode to "C: SPF (SIDE2)." The current back sur-
face off-center adjustment value is displayed in 2 digits on the
display section.
face off-center adjustment value is displayed in 2 digits on the
display section.
7)
Enter a set value and press [OK] key. The correction value is
saved and a copy is made.
saved and a copy is made.
<Adjustment specifications>
Note: Since the copied scale is used as a test chart,
place the scale in parallel to the sides.
㩷 㩷
CLOSE
0
A:
A
㧦 80
B
㧦 50
C
㧦 50
D
㧦 50
㧧 CCD(MAIN)
㧧 CCD(SUB)
㧧
SPF(MAIN)
㧧
SPF(SUB)
SIMULATION
NO.48-01
MAGNIFICATION
ADJUSTMENT
80
㨇
1
㨪99 㨉
OK
TEST
Mode
Specifications
SIM
Set value
Set
range
Magnification
ratio
adjustment
ratio
adjustment
Normal
±1.0%
SIM48-1
<Main scanning
direction>
C: Front surface
E: Back surface
<Sub scanning
direction>
D: Front surface
F: Back surface
<Main scanning
direction>
C: Front surface
E: Back surface
<Sub scanning
direction>
D: Front surface
F: Back surface
Add 1: 0.1%
enlarged.
Subtract 1:
0.1%
reduced.
Default: 50
enlarged.
Subtract 1:
0.1%
reduced.
Default: 50
1 – 99
Mode
Specifications
SIM
Set value
Set
range
Document
off-center
adjustment
off-center
adjustment
Center position
(Default): 3750
pixel
(Default): 3750
pixel
SIM50-12
B: Front
surface
C: Back
surface
B: Front
surface
C: Back
surface
Add 1: Shift to R
side by 0.1mm.
Subtract 1: Shift to
F side by 0.1mm.
side by 0.1mm.
Subtract 1: Shift to
F side by 0.1mm.
1 – 99
0
A:
A
㧦 99
B
㧦 50
㧧 OC
㧧 SPF(SIDE1)
SIMULATION
NO.50-12
ORGINAL CENTER OFFSET SETUP
99
㨇 1㨪 99 㨉
OK
TEST
CLOSE
C
㧦 50
㧧 SPF(SIDE2)