DX-C200. Service Manual - Sharp Copying Equipment Service Manual (repair manual). Page 123

Read Sharp DX-C200 Service Manual online

[5]Replacement and Adjustment 
 
 
 
  5-66 
 
 
 
Fuse 
There is a removable fuse on the PSU. 
 
Fuse No. 
Rating 
FU101: NA 
15 A, 125V 
FU101: EU, ASIA 
6.3A, 250V 
 
 
 
Use a correct rating fuse for the fuse replacement. Never use a wrong rating fuse. If 
do so, the machine may be damaged. 
 
Never try direct connection of PSU circuit without a fuse. 
High Voltage Power Supply Board 
1  Remove all AIO cartridges. 
2.  Operation panel (
  p. 5-6) 
3.  Rear cover (
  p. 5-5) 
4.  Right cover (
  p. 5-7) 
 
5.  High Voltage Power Supply Board [A] (
  x 5, grounding cable x 1, 
  x 1) 
Temperature/Humidity Sensor 
1  Operation panel (
  p. 5-6) 
2  Rear cover (
  p. 5-5) 
3  Right cover (
  p. 5-7) 