Read Sharp AR-PE1 (serv.man29) Technical Bulletin online
Sharp Electronics (UK) Ltd., NIS Systems Support
NIS Bulletin 079
Page: 2 of 3
Procedure:
1. Insert the CD containing the update patches into the CD drive of the
AR-PE1.
2. Using Fiery Downloader or Command Workstation, browse the AR-PE1
CD drive and download the 1-ANKZ9.ps patch (approx 417MB) to the
Direct Queue.
Direct Queue.
3. After the system returns to “Idle”, wait 60 seconds.
4. Reboot the Print Controller.
5. After the Boot sequence finishes, the LCD will display a message that
SP6a is being installed. Once SP6a is completed, the system will boot to
“Idle”.
“Idle”.
6. Reboot the Print Controller again. When the server is “Idle”, print a
configuration page to verify the patch is installed (the Update Information
section should contain the patch number 1-ANKZ9).
section should contain the patch number 1-ANKZ9).
Please Note: Upon Boot, the NT System will now have a password for the
User Administrator – “Fiery.1”
Cont’d
Click on the first or last page to see other AR-PE1 (serv.man29) service manuals if exist.