AR-M700 (serv.man28). Self diag message and troubleshooting - Sharp Copying Equipment Service Manual (repair manual). Page 23

Read Sharp AR-M700 (serv.man28) Service Manual online

AR-M550/M620/M700  SELF DIAG MESSAGE AND TROUBLESHOOTING  9 - 23
Main 
code
Sub 
code
Title
CRUM error
F2
05
Phenomenon
Display
Lamp
Message
Details
Communication with the 
IC chip cannot be made.
Data write failure to the 
CRUM or data read 
failure from the CRUM 
occurs 3 times 
continuously except for 
toner cartridge installation 
detection.
Section
Engine
Operation 
mode
Note 
Case 1
Trouble 
position/
Cause
IC chip trouble
Improper cartridge
Remedy
Insert a proper cartridge.
Note 
Main 
code
Sub 
code
Title
Process control trouble 
(Photoconductor surface reflection 
rate abnormality)
F2
31
Phenomenon
Display
Lamp
Message
Details
Process control trouble 
(Photoconductor surface 
reflection rate abnormality)
Before starting process 
control, the drum surface is 
read by the image density 
sensor to make the sensor 
gain adjustment so that the 
output is fixed to a certain 
level. Though the sensor 
gain is changed, the output 
is not fixed to a certain 
level.
Section
Engine
Operation 
mode
Note 
Case 1
Trouble 
position/
Cause
Image density sensor 
trouble
Remedy
Use SIM 44-02 to perform 
the process control 
sensor gain adjustment.
Note 
Case 2
Trouble 
position/
Cause
Improper connection of 
the harness between the 
PCU PWB and the image 
density sensor
Remedy
If “Error” is displayed, it 
may be considered as a 
breakdown. Check the 
sensor and the harness.
Note 
Case 3
Trouble 
position/
Cause
The image density sensor 
is dirty.
OPC drum cleaning 
trouble
Remedy
If the adjustment is 
completed, check the 
drum surface conditions.
Note 
Main 
code
Sub 
code
Title
Process control trouble (Drum 
marking scan trouble)
F2
32
Phenomenon
Display
Lamp
Message
Details
Process control trouble 
(Drum marking scan 
trouble)
The drum marking size, 
density, or the number of 
units is improper.
Section
Engine
Operation 
mode
Note 
Case 1
Trouble 
position/
Cause
Drum marking sensor 
trouble
Remedy
Use SIM 44-02 to perform 
the process control 
sensor gain adjustment.
Note 
Case 2
Trouble 
position/
Cause
Improper connection of 
the harness between the 
PCU PWB and the drum 
marking sensor
Remedy
If “Error” is displayed, it 
may be considered as a 
breakdown. Check the 
sensor and the harness.
Note 
Case 3
Trouble 
position/
Cause
The drum marking sensor 
is dirty.
OPC drum cleaning 
trouble
Remedy
If the adjustment is 
completed, check the 
drum surface conditions.
Note 
Main 
code
Sub 
code
Title
Drum marking sensor gain 
adjustment error
F2
37
Phenomenon
Display
Lamp
Message
Details
Drum marking sensor 
gain adjustment error
Before starting process 
control, the drum marking 
area surface is read by 
the sensor to make the 
sensor gain adjustment 
so that the output is fixed 
to a certain level. Though 
the sensor gain is 
changed, the output is not 
fixed to a certain level.
Section
Engine
Operation 
mode
Note 
Case 1
Trouble 
position/
Cause
Drum marking sensor 
trouble
Remedy
Use SIM 44-02 to perform 
the process control 
sensor gain adjustment.
Note 
Page of 38
Display

Click on the first or last page to see other AR-M700 (serv.man28) service manuals if exist.