Read Sharp AR-F13 (serv.man2) Service Manual online
AR-F13 TROUBLESHOOTING 9-2
3. Troubleshooting
A. Finisher/saddle unit
(1) F1-03, Paddle Motor Fault (detail code: 01/02/03/04)
(2) F1-10, Staple/fold Motor Fault
F1
34
Content
Console finisher (AR-F13)
punch (AR-PN1) motor trouble
punch (AR-PN1) motor trouble
Detail
Punch motor operation abnormality
Cause
Motor lock
Motor rpm abnormality
Overcurrent to the motor
Console finisher control PWB trouble
Motor rpm abnormality
Overcurrent to the motor
Console finisher control PWB trouble
Check and
remedy
remedy
Use DIAG (SIM3-3) to check the motor
operation.
operation.
35
Content
Console finisher (AR-F13)
punch (AR-PN1) side registration sensor
trouble
punch (AR-PN1) side registration sensor
trouble
Detail
Sensor input value abnormality
Cause
Sensor breakage
Harness disconnection
Console finisher control PWB trouble
Harness disconnection
Console finisher control PWB trouble
Check and
remedy
remedy
Use DIAG (SIM3-2) to check the sensor
operation.
operation.
36
Content
Console finisher (AR-F13)
punch (AR-PN1) timing sensor trouble
punch (AR-PN1) timing sensor trouble
Detail
Sensor input value abnormality
Cause
Sensor breakage
Harness disconnection
Console finisher control PWB trouble
Harness disconnection
Console finisher control PWB trouble
Check and
remedy
remedy
Use DIAG (SIM3-2) to check the sensor
operation.
operation.
F1
37
Content
Console finisher (AR-F13)
backup RAM trouble
backup RAM trouble
Detail
Backup RAM contents are disturbed.
Cause
Console finisher control PWB trouble
Malfunction by noise
Malfunction by noise
Check and
remedy
remedy
Replace the console finisher control PWB.
38
Content
Console finisher (AR-F13)
punch (AR-PN1) backup RAM trouble
punch (AR-PN1) backup RAM trouble
Detail
Punch unit backup RAM contents are
disturbed.
disturbed.
Cause
Punch control PWB trouble
Malfunction by noise
Malfunction by noise
Check and
remedy
remedy
Replace the punch control PWB.
81
Content
Console finisher transport motor abnormality
Detail
Transport motor trouble
Cause
Motor lock
Motor rpm abnormality
Overcurrent to the motor
Console finisher control PWB trouble
Motor rpm abnormality
Overcurrent to the motor
Console finisher control PWB trouble
Check and
remedy
remedy
Use DIAG (SIM3-3) to check the motor
operation.
operation.
Cause/Trouble section
Procedure
Check
Result
Remedy
Paddle home position sensor (PHPS)
1
Check the paddle home position sensor. Is the sensor normal?
NO
Replace the sensor
Swing guide home position sensor
(ARHPS)
(ARHPS)
2
Check the swing guide home position sensor.
Is the sensor normal?
Is the sensor normal?
NO
Replace the sensor.
Wiring
3
Is the wiring between the finisher controller PCB and the paddle
motor normal?
motor normal?
NO
Correct the wiring.
Paddle, Swing guide assembly
4
Try turning the paddle motor clockwise and counterclockwise by
hands. Is there mechanical tapping in the rotation of the paddle
or the up/down movement of the swing guide?
hands. Is there mechanical tapping in the rotation of the paddle
or the up/down movement of the swing guide?
YES
Correct the
mechanical
mechanism.
mechanical
mechanism.
Paddle motor (FPM),
finisher controller PCB
finisher controller PCB
5
Try replacing the paddle motor. Is the problem corrected?
YES
End.
NO
Replace the finisher
controller PCB.
controller PCB.
Cause/Trouble section
Procedure
Check
Result
Remedy
Stapler home position sensor (STHPS)
1
Check the stapler home position sensor. Is the sensor normal?
NO
Replace the sensor.
Wiring
1
Is the wiring between the finisher controller PCB and the staple/
fold motor normal?
fold motor normal?
NO
Correct the wiring.
Stapler unit
2
Try turning the staple jam releasing dial.
Is there mechanical trapping?
Is there mechanical trapping?
YES
Correct the
mechanical system.
mechanical system.
Staple/fold motor (FFSM),
Finisher controller PCB
Finisher controller PCB
3
Try replacing the staple/fold motor. Is the problem corrected?
YES
End.
NO
Replace the finisher
controller PCB.
controller PCB.
Click on the first or last page to see other AR-F13 (serv.man2) service manuals if exist.