Read Sharp AR-C270 (serv.man4) Service Manual online
2 – 14
(3) Operating voltage/power consumption
(AR-C150/C250)
(AR-C160/C270)
4. Safety and environmental protection
standards
A. Safety standards
B. Environmental standards
(1) Power consumption and environmental standards
(2) Ozone level
(3) Noise level
5. Ambient conditions
A. Space required
(1) Area required
B. Operating ambient conditions
(1) Temperature/Humidity
(2) Power supply voltage and frequency
Power supply voltage/
frequency
Power consumption
Main unit
With full options
Preheat
condition
Ready
condition
Sleep mode
condition
Max.
Preheat
condition
Ready
condition
Sleep mode
condition
Max.
100V
50/60Hz
Max. 101W
—
Max. 10W
1500W
—
—
—
1500W
110V
50/60Hz
Max. 101W
—
Max. 10W
1500W
—
—
—
1500W
120V
50/60Hz
Max. 101W
—
Max. 10W
1500W
—
—
—
1500W
127V
50/60Hz
Max. 101W
—
Max. 10W
1500W
—
—
—
1500W
220 to 230V
50/60Hz
Max. 101W
—
Max. 10W
1800W
—
1175W
—
1800W
240V
50/60Hz
Max. 101W
—
Max. 10W
1800W
—
1325W
—
1800W
Power supply voltage/
frequency
Power consumption
Main unit
With full options
Preheat
condition
Ready
condition
Sleep mode
condition
Max.
Preheat
condition
Ready
condition
Sleep mode
condition
Max.
100V
50/60Hz
Max. 128.2wh
(AR-C160)
Max. 135.9wh
(AR-C270)
—
Max. 15W
1500W
—
—
—
1500W
110V
50/60Hz
Max. 128.2wh
—
Max. 15W
1500W
—
—
—
1500W
120V
50/60Hz
Max. 128.2wh
—
Max. 15W
1500W
—
—
—
1500W
127V
50/60Hz
Max. 128.2wh
—
Max. 15W
1500W
—
—
—
1500W
220 to 230V
50/60Hz
Max. 128.2wh
—
Max. 15W
1800W
—
1175W
—
1800W
240V
50/60Hz
Max. 128.2wh
—
Max. 15W
1800W
—
1325W
—
1800W
Item
Standard
Country
Safety standards
S mark (Electrical regulations) Japan
UL
U.S.A
SEMKO
Sweden
GS Mark
Germany
Environmental standards FCC
U.S.A
VCCI
Japan
CE
Europe
C-tick
Australia
Item
Standard
Country
Power consumption
Energy Star
Japan, U.S.A, Europe
ECP, Nordic
Canada
Environmental standards Swan, Nordic
Sweden
Max. 0.02mg/m
3
Model
AR-C150
AR-C250
AR-C250
Max. 63 dB
AR-C160
AR-C270
AR-C270
Max. 68 dB
AR-C150/C160/C250/C270
AR-C100
Main unit
1412 × 695mm (55.6" × 27.4")
1220 × 695mm
With full options
(With AR-SS2)
1454 × 761mm (57.2" × 30.0")
(With AR-FN4)
1668 × 761mm (65.7" × 30.0")
1454 × 761mm (57.2" × 30.0")
(With AR-FN4)
1668 × 761mm (65.7" × 30.0")
—
Power supply voltage
Rated voltage ± 10%
Power supply frequency
Rated frequency ± 2%
15˚C
35˚C
80%
20%
30˚C, 80%
35˚C, 60%
RH
Humidity
Temperature
Click on the first or last page to see other AR-C270 (serv.man4) service manuals if exist.