AR-C270 (serv.man4). (Section 1 2) Configuration Specification - Sharp Copying Equipment Service Manual (repair manual). Page 22

Read Sharp AR-C270 (serv.man4) Service Manual online

2 – 14
(3) Operating voltage/power consumption
(AR-C150/C250)
(AR-C160/C270)
4. Safety and environmental protection 
standards
A. Safety standards
B. Environmental standards
(1) Power consumption and environmental standards
(2) Ozone level
(3) Noise level
5. Ambient conditions
A. Space required
(1) Area required
B. Operating ambient conditions
(1) Temperature/Humidity
(2) Power supply voltage and frequency
Power supply voltage/
frequency
Power consumption
Main unit
With full options
Preheat 
condition
Ready 
condition
Sleep mode 
condition
Max.
Preheat 
condition
Ready 
condition
Sleep mode 
condition
Max.
100V
50/60Hz
Max. 101W
Max. 10W
1500W
1500W
110V
50/60Hz
Max. 101W
Max. 10W
1500W
1500W
120V
50/60Hz
Max. 101W
Max. 10W
1500W
1500W
127V
50/60Hz
Max. 101W
Max. 10W
1500W
1500W
220 to 230V
50/60Hz
Max. 101W
Max. 10W
1800W
1175W
1800W
240V
50/60Hz
Max. 101W
Max. 10W
1800W
1325W
1800W
Power supply voltage/
frequency
Power consumption
Main unit
With full options
Preheat 
condition
Ready 
condition
Sleep mode 
condition
Max.
Preheat 
condition
Ready 
condition
Sleep mode 
condition
Max.
100V
50/60Hz
Max. 128.2wh 
(AR-C160)
Max. 135.9wh 
(AR-C270)
Max. 15W
1500W
1500W
110V
50/60Hz
Max. 128.2wh
Max. 15W
1500W
1500W
120V
50/60Hz
Max. 128.2wh
Max. 15W
1500W
1500W
127V
50/60Hz
Max. 128.2wh
Max. 15W
1500W
1500W
220 to 230V
50/60Hz
Max. 128.2wh
Max. 15W
1800W
1175W
1800W
240V
50/60Hz
Max. 128.2wh
Max. 15W
1800W
1325W
1800W
Item
Standard
Country
Safety standards
S mark (Electrical regulations) Japan
UL
U.S.A
SEMKO
Sweden
GS Mark
Germany
Environmental standards FCC
U.S.A
VCCI
Japan
CE
Europe
C-tick
Australia
Item
Standard
Country
Power consumption
Energy Star
Japan, U.S.A, Europe
ECP, Nordic
Canada
Environmental standards Swan, Nordic
Sweden
Max. 0.02mg/m
3
Model
AR-C150
AR-C250
Max. 63 dB
AR-C160
AR-C270
Max. 68 dB
AR-C150/C160/C250/C270
AR-C100
Main unit
1412 × 695mm (55.6" × 27.4")
1220 × 695mm
With full options
(With AR-SS2) 
1454 × 761mm (57.2" × 30.0")
(With AR-FN4) 
1668 × 761mm (65.7" × 30.0")
Power supply voltage
Rated voltage ± 10%
Power supply frequency
Rated frequency ± 2%
15˚C
35˚C
80%
20%
30˚C, 80%
35˚C, 60%
RH
Humidity
Temperature
Page of 23