Read Sharp AR-C270 (serv.man17) Service Manual online
Simulation
Code
Content/Item
Set range
Default
Model
NOTE
Data store
location
Main Sub.
AR-
C100
AR-
C150
AR-
C250
AR-
C160/
C270
50
01
Copy lead edge
adjustment
adjustment
A: RRC-A (Distance between
MHP and the image lead edge)
0 – 99
50
❍
❍
❍
❍
EEPROM
(PCU PWB)
(PCU PWB)
B: RRC-B (Resist roller ON
timing)
0 – 99
50
❍
❍
❍
❍
C: DEN-A (Lead edge void
quantity)
0 – 99
40
❍
❍
❍
❍
D: DEN-B (Rear edge void
quantity)
0 – 99
30
❍
❍
❍
❍
E: IMAGE LOSS (Lead edge
image loss quantity)
0 – 99
40
❍
❍
❍
❍
02
Lead edge adjustment
(Simple method)
(Simple method)
A: L1
0 – 99
0
❍
❍
❍
❍
EEPROM
(PCU PWB)
(PCU PWB)
B: L2
0 – 99
0
❍
❍
❍
❍
C: DEN-A (Lead edge void
quantity)
0 – 99
40
❍
❍
❍
❍
D: DEN-B (Rear edge void
quantity)
0 – 99
30
❍
❍
❍
❍
E: IMAGE LOSS (Lead edge
image loss)
0 – 99
40
❍
❍
❍
❍
50
10
Paper image off-center
adjustment
adjustment
A: Manual paper feed tray
30 – 70
50
❍
❍
❍
EEPROM
(ICU PWB)
(ICU PWB)
B: Paper feed tray 1
20 – 80
50
❍
❍
❍
❍
C: Paper feed tray 2
20 – 80
50
❍
❍
❍
❍
D: Paper feed tray 3
20 – 80
50
❍
❍
❍
❍
E: Paper feed tray 4
20 – 80
50
❍
❍
❍
❍
F: Large capacity tray (LCC)
30 – 70
50
❍
❍
❍
G: Duplex (ADU)
20 – 80
30
❍
❍
❍
H: (Black) image main scanning
direction print magnification
ratio
ratio
1 – 199
100
❍
❍
❍
❍
12
Original off-center
adjustment
adjustment
A: Original table mode
20 – 80
50
❍
❍
❍
❍
EEPROM
(ICU PWB)
(ICU PWB)
B: RADF mode
20 – 80
50
❍
❍
❍
❍
20
Color image registration
adjustment (Main
scanning direction)
adjustment (Main
scanning direction)
A: Tandem adjustment value
(Cyan)
1 – 199
100
❍
❍
❍
❍
EEPROM
(ICU PWB)
(ICU PWB)
B: Main scanning direction print
magnification ratio adjustment
value (Cyan)
value (Cyan)
1 – 199
100
❍
❍
❍
❍
C: Tandem adjustment value
(Magenta)
1 – 199
100
❍
❍
❍
❍
D: Main scanning direction print
magnification ratio adjustment
value (Magenta)
value (Magenta)
1 – 199
100
❍
❍
❍
❍
E: Tandem adjustment value
(Yellow)
1 – 199
100
❍
❍
❍
❍
F: Main scanning direction print
magnification ratio adjustment
value (Yellow)
value (Yellow)
1 – 199
100
❍
❍
❍
❍
21
Color image registration
adjustment Sub scanning
direction)
adjustment Sub scanning
direction)
A: Black
→
Cyan
1 – 199
100
❍
❍
❍
❍
EEPROM
(ICU PWB)
(ICU PWB)
B: .Cyan
→
Magenta
1 – 199
100
❍
❍
❍
❍
C: Magenta – Yellow
1 – 199
100
❍
❍
❍
❍
D: Print quantity
1 – 999
1
❍
❍
❍
❍
The setup data is not
stored.
stored.
E: Paper (Paper tray)
1 – 6
3
❍
❍
❍
❍
22
Image registration
adjustment (Auto)
adjustment (Auto)
❍
❍
❍
❍
The adjustment value
cannot be entered
directly
cannot be entered
directly
EEPROM
(ICU PWB)
(ICU PWB)
51
01
Separation pawl ON
timing adjustment
timing adjustment
A: Separation pawl operation
timing
30 – 550
290
❍
❍
❍
❍
EEPROM
(PCU PWB)
(PCU PWB)
B: Transfer voltage ON timing
1 – 990
360
❍
❍
❍
❍
C: Transfer voltage OFF timing
1 – 990
510
❍
❍
❍
❍
02
Paper resist quantity
adjustment
adjustment
A: Manual paper feed tray
0 – 99
60 (40)
❍
❍
❍
❍
( ) AR-C160/C270
EEPROM
(PCU PWB)
(PCU PWB)
B: Paper feed tray
0 – 99
60
❍
❍
❍
❍
C: Large capacity paper feed tray
(LCC)
0 – 99
70
❍
❍
❍
❍
D: Duplex (ADU)
0 – 99
70
❍
❍
❍
14 – 16A
Click on the first or last page to see other AR-C270 (serv.man17) service manuals if exist.