Simulation
Code
Content/Item
Set range
Default
Model
NOTE
Data store
location
Main Sub.
AR-
C100
AR-
C150
AR-
C250
AR-
C160/
C270
43
01
Fusing temperature setup
(AR-C250/C160/C270)
(AR-C250/C160/C270)
A: Temperature set value (upper)
70 – 200
❍
❍
The set value
(default) differs
depending on the
destination. Refer to
the details of SIM
43-01.
(default) differs
depending on the
destination. Refer to
the details of SIM
43-01.
EEPROM
(PCU PWB)
(PCU PWB)
B: Temperature set value (lower)
70 – 200
❍
❍
C: Temperature set value (Ready
upper)
70 – 200
❍
❍
D: Temperature set value (Ready
lower)
70 – 200
❍
❍
E: Temperature set value (Energy
saving upper)
70 – 200
❍
❍
F: Temperature set value (Energy
saving reset)
70 – 200
❍
❍
G: Temperature set value (Thick
paper (1) upper)
70 – 210
❍
❍
H: Temperature set value (Thick
paper (1) lower)
70 – 200
❍
❍
I: Temperature set value (Thick
paper (2) upper)
70 – 210
❍
❍
J: Temperature set value (Thick
paper (2) lower)
70 – 200
❍
❍
K: Temperature set value (OHP
upper)
70 – 200
❍
❍
L: Temperature set value (OHP
lower)
70 – 200
❍
❍
07
Fusing oil pump operation
setup
setup
A: Pump ON time
5 – 50
12
❍
❍
❍
❍
EEPROM
(PCU PWB)
(PCU PWB)
B: Pump interval time
17 – 250
130
❍
❍
❍
❍
44
01
Image density correction
(Process control)
operation mode setup
(Process control)
operation mode setup
Operation mode
All ON
❍
❍
❍
❍
EEPROM
(PCU PWB)
(PCU PWB)
04
Image density correction
(Process control) target
level setup
(Process control) target
level setup
A: Color image density sensor
0 – 200
102
❍
❍
❍
❍
EEPROM
(PCU PWB)
(PCU PWB)
B: Black image density sensor
0 – 200
133
❍
❍
❍
❍
C: Target density level (Yellow)
0 – 200
90
❍
❍
❍
❍
D: Target density level (Magenta)
0 – 200
100
❍
❍
❍
❍
E: Target density level (Cyan)
0 – 200
83
❍
❍
❍
❍
F: Target density level (Black)
0 – 200
15
❍
❍
22
❍
❍
05
Image density correction
(Process control) initial
developing bias voltage
setup
(Process control) initial
developing bias voltage
setup
A: (Black)
0 – 700
325
❍
❍
❍
❍
EEPROM
(PCU PWB)
(PCU PWB)
B: (Cyan)
0 – 700
325
❍
❍
❍
❍
C: (Magenta)
0 – 700
325
❍
❍
❍
❍
D: (Yellow)
0 – 700
325
❍
❍
❍
❍
06
Image forming section
correction (Process
control) forcible execution
correction (Process
control) forcible execution
❍
❍
❍
❍
The adjustment value
cannot be entered
directly.
cannot be entered
directly.
EEPROM
(PCU PWB)
(PCU PWB)
13
Image density sensor
sense level adjustment
sense level adjustment
Sensor LED level
0 – 255
128
❍
❍
❍
❍
The adjustment value
cannot be entered
directly.
cannot be entered
directly.
EEPROM
(PCU PWB)
(PCU PWB)
Dark voltage level
0 – 255
30
❍
❍
❍
❍
Calibration sheet sense level
0 – 255
102
❍
❍
❍
❍
Calibration plate sense level
0 – 255
80
❍
❍
❍
❍
20
OPC drum phase
adjustment (Old)
adjustment (Old)
A: Print mode
1 – 3
3
❍
❍
The set up data is
not stored.
not stored.
EEPROM
(PCU PWB)
(PCU PWB)
B: Cyan OPC drum phase
0 – 330
60
❍
❍
C: Magenta OPC drum phase
0 – 330
120
❍
❍
D: Yellow OPC drum phase
0 – 330
180
❍
❍
E: Paper (Paper tray)
1 – 6
5
❍
❍
The set up data is
not stored.
not stored.
21
Half tone image correction
initial setup
initial setup
Initial setup data
0 – 255
—
❍
❍
❍
❍
The set up data
cannot be entered
directly.
cannot be entered
directly.
EEPROM
(ICU PWB)
(ICU PWB)
23
Image density sensor
sense position adjustment
sense position adjustment
Adjustment value
40 – 60
50
❍
❍
❍
❍
The adjustment value
cannot be entered
directly.
cannot be entered
directly.
EEPROM
(ICU PWB)
(ICU PWB)
26
Half tone image correction
forcible execution
forcible execution
Correction data
245 – 755
(1 – 1999)
∗
1
500
(1000)
∗
1
❍
❍
❍
❍
The correction data
cannot be entered
directly.
cannot be entered
directly.
EEPROM
(ICU PWB)
(ICU PWB)
27
Half tone image correction
data reset
data reset
Correction data
245 – 755
(1 – 1999)
∗
1
500
(1000)
∗
1
❍
❍
❍
❍
EEPROM
(ICU PWB)
(ICU PWB)
∗
1: AR-C160/C270
14 – 11A