AR-C270 (serv.man17). (Section 14) Others - Sharp Copying Equipment Service Manual (repair manual). Page 5

Read Sharp AR-C270 (serv.man17) Service Manual online

Simulation
Code
Content/Item
Set range
Default
Model
NOTE
Data store
location
Main Sub.
AR-
C100
AR-
C150
AR-
C250
AR-
C160/
C270
43
01
Fusing temperature setup
(AR-C250/C160/C270)
A: Temperature set value (upper) 
70 –  200
The set value
(default) differs
depending on the
destination. Refer to
the details of SIM
43-01.
EEPROM
(PCU PWB)
B: Temperature set value (lower)
70 –  200
C: Temperature set value (Ready
upper)
70 –  200
D: Temperature set value (Ready
lower)
70 –  200
E: Temperature set value (Energy
saving upper) 
70 –  200
F: Temperature set value (Energy
saving reset)
70 –  200
G: Temperature set value (Thick
paper (1) upper) 
70 –  210
H: Temperature set value (Thick
paper (1) lower) 
70 –  200
I: Temperature set value (Thick
paper (2) upper)
70 –  210
J: Temperature set value (Thick
paper (2) lower)
70 –  200
K: Temperature set value (OHP
upper)
70 –  200
L: Temperature set value (OHP
lower)
70 –  200
07
Fusing oil pump operation
setup
A: Pump ON time 
5 –  50
12
EEPROM
(PCU PWB)
B: Pump interval time 
17 –  250
130
44
01
Image density correction
(Process control)
operation mode setup
Operation mode
All ON
EEPROM
(PCU PWB)
04
Image density correction
(Process control) target
level setup
A: Color image density sensor
0 –  200
102
EEPROM
(PCU PWB)
B: Black image density sensor
0 –  200
133
C: Target density level (Yellow)
0 –  200
90
D: Target density level (Magenta)
0 –  200
100
E: Target density level (Cyan)
0 –  200
83
F: Target density level (Black)
0 –  200
15
22
05
Image density correction
(Process control) initial
developing bias voltage
setup 
A: (Black)
0 –  700
325
EEPROM
(PCU PWB)
B: (Cyan)
0 –  700
325
C: (Magenta)
0 –  700
325
D: (Yellow)
0 –  700
325
06
Image forming section
correction (Process
control) forcible execution
The adjustment value
cannot be entered
directly.
EEPROM
(PCU PWB)
13
Image density sensor
sense level adjustment
Sensor LED level
0 –  255
128
The adjustment value
cannot be entered
directly.
EEPROM
(PCU PWB)
Dark voltage level 
0 –  255
30
Calibration sheet sense level
0 –  255
102
Calibration plate sense level
0 –  255
80
20
OPC drum phase
adjustment (Old)
A: Print mode
1 –   3
3
The set up data is
not stored.
EEPROM
(PCU PWB)
B: Cyan OPC drum phase
0 –  330
60
C: Magenta OPC drum phase
0 –  330
120
D: Yellow OPC drum phase
0 –  330
180
E: Paper (Paper tray)
1 –   6
5
The set up data is
not stored.
21
Half tone image correction
initial setup
Initial setup data
0 –  255
The set up data
cannot be entered
directly.
EEPROM
(ICU PWB)
23
Image density sensor
sense position adjustment
Adjustment value 
40 –  60
50
The adjustment value
cannot be entered
directly.
EEPROM
(ICU PWB)
26
Half tone image correction
forcible execution
Correction data
245 –  755
(1 –  1999) 
1
500
(1000) 
1
The correction data
cannot be entered
directly. 
EEPROM
(ICU PWB)
27
Half tone image correction
data reset
Correction data
245 –  755
(1 –  1999) 
1
500
(1000) 
1
EEPROM
(ICU PWB)
1: AR-C160/C270
14 –  11A
Page of 13
Display

Click on the first or last page to see other AR-C270 (serv.man17) service manuals if exist.