AR-C270 (serv.man10). (Section 7) Settings Adjustments M11-M16 - Sharp Copying Equipment Service Manual (repair manual). Page 4

Read Sharp AR-C270 (serv.man10) Service Manual online

11) Insert the slide pin as shown below, and make positioning in the
sub scanning direction. (Initial positioning is completed.)
12) Make a copy in the initial position and check the copy
magnification ratio again.
If the copy magnification ratio is not in the range of 100 
±
 1%, perform
the following procedure.
Repeat procedures 12) and 13) until the copy magnification ratio is
within the range of 100 
±
 1%.
When the copy image is longer than the original, move in the
direction of B.
When the copy image is shorter than the original, move in the
direction of A.
One scale of scribe line corresponds to 0.2%.
13) Change the installing position in the CCD sub scanning direction
to adjust the magnification ratio.
NOTE: Due to the structure of the optical system, when the CCD unit
fixing position is changed with SIM 48-1 set to 50, the copy
magnification ratio is adjusted to the specified level (100 
±
1.0%) and the specified resolution is provided.
ADJ M13
Sub scanning direction copy
magnification ratio adjustment
This adjustment must be performed in the following cases:
When the copy magnification ratio in the copy image sub scanning
direction is improper.
When the scanner motor is replaced.
When the scanner motor control PWB is replaced.
When a U2 trouble occurs.
When the PCU main PWB is replaced.
When the EEPROM of the PCU main PWB is replaced.
Before this adjustment, perform the focus adjustment (CCD unit in-
stalling position adjustment).
1) Place a scale on the original table as shown below.
2) Enter the SIM 48-1 mode.
3) Make a normal copy and obtain the copy magnification ratios.
Copy magnification ratio
 = 
(
Original 
dimension
 –  Copy dimension
)
Original dimension
 
×
 100 [%]
4) Check that the copy magnification ratio is within the specified
range (100 
±
 1%).
If the copy magnification ratio is within the specified range (100 
±
1%), the adjustment is completed.
If not, perform the following procedure.
5) Change the scan mode adjustment value of SIM 48-1.
When the adjustment value is increased, the sub scanning direc-
tion copy magnification ratio is increased.
A change in the adjustment value by 1 corresponds to a change in
the copy magnification ratio by about 0.1%.
Repeat procedures 3) –  5) until the coy magnification ratio is
within the specified range (100 
±
 0.28%).
NOTE: Fix the adjustment value of SIM 48-1 adjustment mode (F –
R) to 50.
ADJ M14
Image position adjustment (Main
scanning direction) (Print engine)
This adjustment must be performed in the following cases:
When the paper tray is replaced.
When the paper tray section is disassembled.
When the manual paper feed tray is replaced.
When the manual paper feed tray is disassembled.
When the duplex section is disassembled.
When the duplex section is installed or replaced.
When the large capacity paper feed tray is installed or replaced.
When the large capacity paper feed tray is disassembled.
When a U2 trouble occurs.
When the PCU main PWB is replaced.
When the EEPROM of the PCU main PWB is replaced.
1) Enter the SIM 50-10 mode.
2) Select the paper feed mode to be adjusted with the scroll key.
3) Press the [EXECUTE] key.
The adjustment pattern is printed.
A
B
10 20 30 40 50 60 70 80 90 50 100 110 120130 140
10
20
90
100
110
10
20
90
100
110
10
20
90
100
110
(Example 2) 
Copy B longer 
than the original
(Example 1) 
Copy A shorter 
than the original
Scale 
(Original)
7 –  21
Page of 6
Display