AR-C260/C260M SIMULATION 9 - 57
(
63
-03
Purpose
Adjustment
Function
(Purpose)
(Purpose)
Used to adjust the CCD color balance (gamma).
Section
Scanner (Image scanning)
Item
Picture quality
Color balance
Operation/
Procedure
Procedure
Set the SIT chart (UKOG-0280FCZZ) on the document
table, and press the [EXECUTE] key. The color
coefficient automatic adjustment pattern reading is
started to calculate and display the color coefficient
data.
The color coefficient data of each color can be displayed
with the color key.
table, and press the [EXECUTE] key. The color
coefficient automatic adjustment pattern reading is
started to calculate and display the color coefficient
data.
The color coefficient data of each color can be displayed
with the color key.
63
-05
Purpose
Setting
Function
(Purpose)
(Purpose)
Used to set the CCD color balance (gamma) default.
Section
Scanner (Image scanning)
Item
Picture quality
Color balance
Operation/
Procedure
Procedure
1. Press the [EXECUTE] key, and the [YES] and [NO]
keys become active.
2. When the [YES] key is pressed, the CCD color
balance value is set to the default.
63
-06
Purpose
Adjustment/Operation data output check (display, print)
Function
(Purpose)
(Purpose)
Used to check the color balance (gamma) check patch.
Section
Image process (ICU)
Item
Picture quality
Color balance
Operation/
Procedure
Procedure
1. Set the color balance check patch printed with SIM
46-21 on the document table.
2. Press the [EXECUTE] key, and the reading is started
and the data are displayed on the display.
63
-07
Purpose
Setting
Function
(Purpose)
(Purpose)
Used to set the target color balance (gamma) for auto
color balance adjustment. The standard color balance
(gamma) or an optional color balance (gamma) is set as
the service target.
color balance adjustment. The standard color balance
(gamma) or an optional color balance (gamma) is set as
the service target.
Section
Image process (ICU)
Item
Picture quality
Color balance
Operation/
Procedure
Procedure
1. In the copy color balance adjustment (manual
adjustment) (SIM 46-21) mode, the color patch
image (adjustment pattern) is outputted. (This must
be adjusted properly.)
image (adjustment pattern) is outputted. (This must
be adjusted properly.)
2. Press the [SETUP] key.
3. Set the color patch image (adjustment pattern) paper
3. Set the color patch image (adjustment pattern) paper
printed in the copy color balance adjustment (manual
adjustment) (SIM 46-21) mode on the document
table.
adjustment) (SIM 46-21) mode on the document
table.
4. Press the [EXECUTE] key. The color patch image
(adjustment pattern) is read.
5. Press the REPEAT key and perform procedure 4
again.
6. Press the [OK] key.
The color balance corresponding to the color patch
image (adjustment pattern) printed in the copy color
balance adjustment (manual adjustment) is set as the
service target.
The color balance corresponding to the color patch
image (adjustment pattern) printed in the copy color
balance adjustment (manual adjustment) is set as the
service target.
63
-08
Purpose
Setting
Function
(Purpose)
(Purpose)
Used to set the target color balance (gamma) for auto
color balance adjustment (SIM 46-24). The service
target is set to the default (standard) color balance
(gamma).
color balance adjustment (SIM 46-24). The service
target is set to the default (standard) color balance
(gamma).
Section
Scanner (Image scanning)
Item
Picture quality
Color balance
Operation/
Procedure
Procedure
1. Press the [EXECUTE] key.
2. Press the [YES] key.
2. Press the [YES] key.
The service target is set to the default (standard) color
balance (gamma).
balance (gamma).