AR-C260/C260M  SETTING AND ADJUSTMENTS  8 - 2
Since the output voltage cannot be checked directly due to the
machine structure, the adjustment value of the simulation is set to the
default (specified value) to perform the adjustment.
This adjustment must be performed in the following cases:
• When the high voltage power PWB is replaced.
• When a U2 trouble occurs.
• When the PCU PWB is replaced.
• When the EEPROM of the PCU PWB is replaced.
1) Enter the SIM 8-2 mode.
SIM 8-2
2) Select the output mode to be adjusted with the color key and scroll
key.
3) Enter the adjustment value (specified value), and press the [OK]
key.
By entering the default value (specified value), the specified volt-
age is outputted.
Remark: When the default value is set, the specified voltage is output-
ted. 
There is, therefore, no need to check the output voltage
unless there is a doubt for any abnormality in the output volt-
age. 
If there is a need to check that the normal voltage is output-
ted or to adjust by referring to the output voltage, use the
method below.
1) Remove the rear cover of the machine. 
2) Remove the image process fan motor and the duct.
3) Connect the high voltage adjustment harnesses (DHAi-3471FCZZ/
DHAi-3472FCZZ) with the connectors CNMON and CNMONK on
the high voltage PWB.
4) Enter the SIM8-2 mode.
5) Select the output mode to be adjusted with the color key and the
scroll key. 
6) Check that the pin numbers of the connectors CNMON and
CNMONK are properly assigned to the connector pin numbers of
the high voltage adjustment harness. 
7) Apply a digital multi-meter to the connector pins of the high voltage
adjustment harness corresponding to the output mode to be
adjusted.
ADJ 1
High voltage adjustment
ADJ 1A
Main charger grid voltage adjustment
Color
Item Operation 
mode
Adjustment value
Main charger grid voltage
Monitor (High voltage PWB)
Pin 
No.
Actual 
voltage
Adjustment 
range
Specified 
value 
(Default)
Monitor voltage 
(Specified value)
Connector
K
A: HIGH SPEED
High speed (140mm/s) (B & W)
180 – 700
620
53.5 ± 0.2v
CNMONK
1
–620v
B: MIDDLE SPEED
Middle speed (117mm/s) (Color) (B & W)
180 – 700
620
53.5 ± 0.2v
CNMONK
1
–620v
C: LOW SPEED
Low speed (58.5mm/s) (Color) (B & W) 
(Special paper)
180 – 700
590
50.6 ± 0.2v
CNMONK
1
–590v
C
A: MIDDLE SPEED
Middle speed (117mm/s) (Color) (B & W)
180 – 700
620
53.5 ± 0.2v
CNMON
3
–620v
B: LOW SPEED
Low speed (58.5mm/s) (Color) (B & W) 
(Special paper)
180 – 700
590
50.6 ± 0.2v
CNMON
3
–590v
M
A: MIDDLE SPEED
Middle speed (117mm/s) (Color) (B & W)
180 – 700
620
53.5 ± 0.2v
CNMON
7
–620v
B: LOW SPEED
Low speed (58.5mm/s) (Color) (B & W) 
(Special paper)
180 – 700
590
50.6 ± 0.2v
CNMON
7
–590v
Y
A: MIDDLE SPEED
Middle speed (117mm/s) (Color) (B & W)
180 – 700
620
53.5 ± 0.2v
CNMON
11
–620v
B: LOW SPEED
Low speed (58.5mm/s) (Color) (B & W) 
(Special paper)
180 – 700
590
50.6 ± 0.2v
CNMON
11
–590v
A
B
Page of 38