43
43 - 1
Purpose
Setting
Function
(Purpose)
Used to set the fusing temperature in each operation
mode.
Section
Fixing (Fusing)
Item
Operation
Operation/
Procedure
1. Select the kind of lamps and the operation mode
with [
], [
] keys.
2. Enter the set value with the 10-key.
3. Press the [OK] key to set the fusing temperature set in proce-
dure 2.
(AR-C100/C150)
Display
Content
Set
range
Set value
NOTE
U.S.A Canada
Inch
Japan
AB_B
Europe
U.K
Aus.
AB_A
A: HL1 PLAIN
  PAPER
Normal mode control
temperature (HL1)
70 to
200
180
180
180
170
170
180
180
180
180
B: HL2 PLAIN
  PAPER
Normal mode control
temperature (HL2)
70 to
200
135
135
135
125
125
135
135
135
135
C: HL1 READY
Ready state control
temperature (H1)
70 to
200
187
187
187
177
177
187
187
187
187
D: HL2 READY
Ready state control
temperature (H2)
70 to
200
142
142
142
132
132
142
142
142
142
E: HL1 E_STAR
Energy save mode control
temperature (HL1)
70 to
200
140
140
140
140
(137)
140
140
140
140
140
( )
AR-C100
F: HL1 PRE_BK
Control temperature (HL1)
when resetting to B/W
from preheat 
70 to
200
155
155
155
155
(152)
155
155
155
155
155
( )
AR-C100
G: HL1
  HEAVYPAPER
Heavy paper mode control
temperature (HL1)
70 to
200
200
200
200
200
200
200
200
200
200
AR-C150
only
H: HL2
  HEAVYPAPER
Heavy paper mode control
temperature (HL2)
70 to
200
155
155
155
155
155
155
155
155
155
AR-C150
only
I: HL1
  TRANSPARENCY
OHP mode control
temperature (HL1)
70 to
200
180
180
180
180
180
180
180
180
180
AR-C150
only
J: HL2
  TRANSPARENCY
OHP mode control
temperature (HL2)
70 to
200
175
175
175
175
175
175
175
175
175
AR-C150
only
(AR-C250/C160/C270)
Display
Content
Set
range
Set value
NOTE
U.S.A Canada
Inch
Japan AB_B Europe
U.K
Aus.
AB_A
A: HL1 PLAIN
  PAPER
Normal mode control
temperature (HL1)
70 to
200
170
170
170
170
170
170
170
170
170
B: HL2 PLAIN
  PAPER
Normal mode control
temperature (HL2)
70 to
200
125
125
125
140
(125)
140
(125)
125
125
125
125
( )
AR-C160/C270
C: HL1 READY
Ready state control
temperature (H1)
70 to
200
177
177
177
177
177
177
177
177
177
D: HL2 READY
Ready state control
temperature (H2)
70 to
200
132
132
132
140
(132)
140
(132)
132
132
132
132
( )
AR-C160/C270
E: HL1 E_STAR
Energy save mode control
temperature (HL1)
70 to
200
136
(146)
136
(146)
136
(146)
136
(146)
136
(146)
136
(146)
136
(146)
136
(146)
136
(146)
( )
AR-C160/C270
F: HL1 PRE-BK
Control temperature (HL1)
when resetting to B/W
from preheat 
70 to
200
148
(158)
148
(158)
148
(158)
148
(158)
148
(158)
148
(158)
148
(158)
148
(158)
148
(158)
( )
AR-C160/C270
G: HL1
  HEAVYPAPER1
Heavy paper 1 mode
control temperature (HL1)
70 to
210
185
185
185
185
185
185
185
185
185
H: HL2
  HEAVYPAPER1
Heavy paper 1 mode
control temperature (HL2)
70 to
200
155
155
155
155
155
155
155
155
155
I: HL1
  HEAVYPAPER2
Heavy paper 2 mode
control temperature (HL1)
70 to
210
200
200
200
200
200
200
200
200
200
J: HL2
   HEAVYPAPER2
Heavy paper 2 mode
control temperature (HL2)
70 to
200
155
155
155
155
155
155
155
155
155
K: HL1
  TRANSPARENCY
OHP mode control
temperature (HL1)
70 to
200
180
180
180
180
180
180
180
180
180
L: HL2
  TRANSPARENCY
OHP mode control
temperature (HL2)
70 to
200
175
175
175
175
175
175
175
175
175
8 –  17