SIM No.
Content
Set value
U.S.A
Canada
Inch
Japan
AB_B
Europe
U.K.
Aus.
AB_A
SIM26-02 Manual feed paper kind display
2
2
2
0
1
1
1
1
1
SIM26-02 LEGAL  set  value
0
0
0
0
0
0
0
P
O
SIM26-28 AC power voltage
120
120
120
100
100
230
230
230
230
SIM26-30 CE mark Enable/Disable
0
0
0
0
0
1
1
1
1
SIM26-52 White paper exit count up
1
1
1
0
1
1
1
O
1
SIM26-55 Thick paper image process
mode setup
DISABLE
DISABLE
DISABLE
DISABLE
DISABLE
DISABLE DISABLE DISABLE
DISABLE
SIM43-1A Normal mode control
temperature (HL1)
170
170
170
170
170
170
170
170
170
SIM43-1B Normal mode control
temperature (HL2)
125
125
125
125
125
125
125
125
125
SIM43-1C Ready state control
temperature (HL1)
177
177
177
177
177
177
177
177
177
SIM43-1D Ready state control
temperature (HL2)
132
132
132
132
132
132
132
132
132
SIM43-1E Control temperature in the
energy-save mode (HL1)
146
146
146
146
146
146
146
146
146
SIM43-1F Control temperature when
resetting from pre-heat to
monochrome (HL1)
158
158
158
158
158
158
158
158
158
SIM43-1I
Control temperature in the
thick mode 2 (HL1)
200
200
200
200
200
200
200
200
200
SIM43-1J Control temperature in the
thick mode 2 (HL2)
155
155
155
155
155
155
155
155
155
SIM43-1K OHP mode control
temperature (HL1)
180
180
180
180
180
180
180
180
180
SIM43-1L OHP mode control
temperature (HL2)
175
175
175
175
175
175
175
175
175
SIM48-6C Fusing motor speed correction
adjustment value (L)
50
50
50
55
55
50
50
50
50
SIM48-6D Fusing motor speed correction
adjustment value (S)
55
55
55
60
60
55
55
55
55
26 - 32
Purpose
Setting
Function
(Purpose)
Used to set the fan rotating speed (low speed).
Item
Operation
Operation/
Procedure
1. Select the fan motor whose speed is to be adjusted
with [
] and [
] keys and press the [OK] key.
2. Enter the adjustment value with the 10-key.
3. Press the [OK] key.
The adjustment value entered in procedure 2 is set.
In the fan motor low speed rotation mode (ready condition), the ro-
tating speed is controlled with this adjustment value.
The adjustment value means PWM duty %.
Default value
VFM
: Exhaust fan motor 1
15
VFM (HEAT) : Exhaust fan motor 1 (Pre-heating)
15
CFM1
: Optical cooling fan motor 1
0
LSUFM
: LSU cooling fan motor
15
DCFM
: DC power cooling fan motor
0
(AR-C160/C270)
8 –  15
Page of 127