Appendix C: Updating the Software
 
AXIS 700 User’s Manual
 
70
 
Updating the Flash Memory 
To upgrade over the network you will need the following:
The file with the new AXIS 700 software. The name of the file is 
of the form 
product-version.bin
, i.e. 
700-1_10.bin
 for 
software release 1.10 of the AXIS 700.
A computer on the network with TCP/IP and FTP.
Follow these steps to upgrade the AXIS 700 software:
1. Log in to the AXIS 700 with the command 
ftp <Internet 
address>
 
where 
<Internet address>
 is the name or Internet 
address assigned to the AXIS 700.
2. You will be prompted for user id and password. Use the user id 
root
 
which has the default password 
pass.
3. Issue the command 
bin
 to change to binary transfer mode.
4. Issue the command
 put <software name> flash
 where 
<software name>
 is the name of the new software, e.g. 
700-
1_10.bin
.
5. During the flash load, the AXIS 700 LCD will display the message 
Upgrading server
” and a progress bar. Wait for the flash load to 
finish. This normally takes 1 to 4 minutes. The unit will then 
automatically restart with the new AXIS 700 software.
Caution!
Be careful not to interrupt the file transfer. If the transfer is 
interrupted, the AXIS 700 may have to be re-initialized by your 
dealer. 
6. Log out using the command 
quit
bye
 or 
exit
 depending on your 
FTP version.
Notes:
† If you are using a window-based FTP client application such as 
Ws_ftp or Fetch, you must rename the new file 
<software 
file>
 to 
flash
 before downloading.
Page of 83