Read Sharp AR-810 (serv.man4) Service Manual online
AR-651/810 ADJUSTMENT
3 - 42
When opening the RADF, adjust the bracket
position so that the switch is turned on when the
front side height becomes 40~45mm (within the
empty weight falling limit).
40 ~ 45mm
3. 11. 4. Adjustment of RADF open/close switch
3. 11. 5. Adjustment of RADF height
The height is adjusted with 2 adjustment screws at
hinges.
Adjust the height so that the platen guide holders
(front, rear) touch the ADF original glass.
Adjustment screw
Platen guide holder
Platen sheet
ADF original glass
Original glass