AR-651 (serv.man58). ROM upgrading (4) - Sharp Copying Equipment Technical Bulletin (repair manual). Page 6

Read Sharp AR-651 (serv.man58) Technical Bulletin online

ARE543
Sharp Electronics (UK) Ltd., Technical Services Group
 - In case that [1] is set for the code [08-502], please be sure to use the Scanner ROM (Ver.07 or later) for
combination.
5.Change of Default in All Clear
1) PM Support Mode related code (08) * Default is mentioned for e-STUDIO
550/650/810 in order.
Standards for Change (Tolerance: 0~99999999)
Code<Procedure>
Default (×1000)
Tandem LCF Pickup Roller
2302<1>
300/300/300 
 400/400/400
Tandem LCF Paper
Feed Roller
2322<1>
300/300/300 
 400/400/400
Tandem LCF Separation
Roller
2342<1>
300/300/300 
 400/400/400
2) Adjustment Mode (05)
Code
Item Adjusted
Target Function
Default
Tolerance
676-4
PRT
10 
 
7
0~10
677-4
Printer Image
Density
Adjustment
Toner Save
PRT
10 
 
7
0~10
6. Addition of Check function for Middle Transfer Sensor Input Data
Input Data Check (Test Mode 03)
[OFF] in [Power Save] Key (LED for [Power Save] is turned off.)
Numeric keypad
Icon
Items
Conditions in highlighted display
[6]
A
Middle Transfer
Sensor
No Paper
Page of 8
Display