AR-651/810  POWER SUPPLY UNIT  17 - 3
(4) 24V
24VF
: J408
1pin, 2pin
Output to RADF
24VG
: J406
4pin
Output to LGC board
There are 3 output channels which work with the door switch.
(1) 5.1V
5.1VA
: J403
3pin
Output to PLG board
(2) 24V
24VA
: J402
1pin
Output to LGC board
24VB
: J402
2pin
Output to LGC board
24VC
: J402
3pin
Output to LGC board
24VD
: J403
1pin
Output to PLG board
24VE
: J404
5pin
Output to SLG board
24VH
: J409
3pin, 4pin
Output to Finisher
(3) 36V
36VA
: J402
7pin
Output to LGC board
36VB
: J402
8pin
Output to LGC board
36VC
: J404
1pin, 2pin
Output to SLG board