AR-505 (serv.man9). AR505 Service Manual-Simulation - Sharp Copying Equipment Service Manual (repair manual). Page 5

Read Sharp AR-505 (serv.man9) Service Manual online

Code
Function (Purpose)
Main
Sub
24
9
Used to clear the printer print counter. (The counter is cleared
after completion of maintenance.)
11
Used to reset the developer rotation time counter. (The
developer counter of the installed developing unit is reset.)
(AR-501/505 only)
25
1
Used to check the operation of the main drive (excluding the
scanner section) and to check the operation of the toner
concentration sensor. (The toner concentration sensor output
can be monitored.)
2
Used to make the initial setting of toner concentration when
replacing developer.
8
Used to set the timing of toner concentration control
correction B and the correction quantity. The timing is
determined according to the acuumulated use time of
developer. (AR-501/505 only)
26
1
Used to set options. (This simulation is used to make option
setting when an option is installed.)
2
1) Used to set the paper size of the large quantity paper 
   tray. (When the paper size is changed, the lift paper 
   size must be also changed with this simulation.)
2) Used to detect the paper or document size of 8.5" x 
   13" (Inch series) and set the display mode. (All paper 
   feed modes)
3
Used to set the specifications of the auditor. Setting must be
made depending on the use condition of the auditor.
5
Used to set the count mode of the total counter and the
maintenance counter.
6
Used to set the specifications depending on the destination.
15
Used to set the fusing operation mode (paper curl
corresponding mode).
18
Used to set VALID/INVALID of toner save operation. (This
simulation is valid only in the Japan and UK versions. (It
depends on SIM 26-6 (Destination setting). For the other
destinations, the same setting can be executed with the user
program.)
22
Used to set the specification (language display) for the
destination. (Excluding the Japan models.)
30
Used to set the CE mark conforming operation mode.
(For flickers when driving the fusing heater lamp.)
35
Used to set whether the trouble history display of SIM 22-4 is
displayed as one trouble or as the number of continuous
troubles when two or more troubles of a same kind occured.
36
Used to set the ICU fan operating temperature. (Operation in
the pre-heat mode.) (Excluding Japan models.)
40
Polygon motor stop mode setup (AR-501/505)
Used to set the stop time of the polygon motor after leaving in
ready state and to set Enable/Disable of the setting.  (Other
models)
41
Used to enable/disable the auto magnification ratio select
(AMS) function in the pamphlet copy mode.
44
Used to set the model of the unit which is connected to the
SCSI I/F of ICU PWB.
50
Used to set YES/NO of black/white reversion is allowed.
52
Used to set whether white paper discharge count up is
performed or not.
("White paper" means insertion paper in the OHP insertion
paper mode (without copy), cover paper in the cover paper
insertion mode (without copy)/back cover, and white paper in
the duplex exit mode (CA etc.).)
27
1
Used to set the operation  specifications when a
communication trouble occurs between the host computer
and MODEM (on the copier). (When a communication trouble
occurs between the host computer and MODEM (copier), the
self diag display (U7-00) is printed and setting is made to
select inhibit/allow of printing.)
2
Used to set and change the host computer/MODEM
numbers. (This setting is required when a communication is
made between the copier and a computer through MODEM.)
3
Used to set and change the ID numbers of the copier and the
host computer/MODEM numbers. (This setting is required
when a communication is made between the copier and a
computer through MODEM.)
Code
Function (Purpose)
Main
Sub
27
4
Used to enter the start time and the end time of servicing for
management of service work. (The data can be checked by
the host computer.)
5
Used to enter the TAG No. of the copier. (This simulation
allows to check the machine TAG No. with the host
computer.)
30
1
Used to check the operation of sensors and detectors in the
paper feed section, the paper transport section, and the
paper exit section, and the related circuit.
2
Used to check the operation of sensors and detectors in the
paper feed section and the related circuits. 
(The operations of sensors and detectors in the paper feed
section can be monitored with the LCD.)
40
1
Used to check the operation of the manual paper feed tray
paper size detector and the related circuit. (The operation of
the manual paper feed tray paper size detector can be
monitored with the LCD.)
2
Used to adjust the manual paper feed tray paper width
detector detection level.
41
1
Used to check the operation of the document size sensor and
the related circuit. (The operation of the document size
sensor can be monitored with the LCD.)
2
Used to adjsut the document size sensor detection level.
3
Used to check the operation of the document size sensor and
the related circuit. (The document size sensor output level
can be monitored with the LCD.)
43
1
Used to set the fusing temperature in each operation mode.
3
Used to adjust the fusing motor speed. (AR-501/505 only)
8
Used to set the time to rotate the fusing motor after reaching
the set temperature in warming up. (AR-501/505 only)
44
1
Used to set whether the correction functions of the image
forming (process) section are valid or not.
2
Used to adjust the sensitivity (gain) of the OPC drum mark
sensor and the image density sensor.
4
Used to set the target image (reference) density level in the
developing bias voltage correction.
5
Used to set various parameters (main charger grid voltage,
laser beam power, correction start developing bias voltage) in
developing bias correction.
9
Used to check the data on the result of the image forming
section correction (process correction) (the corrected main
charger grid voltage in each print mode, developing bias
voltage, the laser power, etc.)
(This simulation allows to check whether the correction is
executed properly or not.)
12
Used to check the toner image patch density date in
correction operation of the image forming section. (This
simulation allows to check whether the correction is executed
properly or not. )
15
Used to set the correction values of various parameters
(maincharger grid voltage, laser beam power, developing bias
voltage) in the image forming operation and image forming
section correction for OPC drum type A.
(AR-250/280/281/285/286/335/336/405 only)
46
2
Used to adjust the copy density in the copy mode
(binary/multi-value - auto, character and photo, photo mode). 
(The overall print density in each mode (all of the specified
density set for each density level (display value)) can be
adjusted in each mode.)
3
Used to adjust the copy density in the copy mode (multi
value-auto, character and photo, photo mode). 
(The overall print density in each mode (all of the specified
density set for each density level (display value)) can be
adjusted in each mode.) (AR-250/280/285/330/335 only)
5
Used to adjust the print density for each density level (display
value) in the copy mode (multi character mode).
An arbitrary print density can be set for each density level
(display value). (AR-250/280/285/330/335 only)
6
Used to adjust the print density for each density level (display
value) in the copy mode (multi value-character, photo mode). 
An arbitrary print density can be set for each density level
(display value). (AR-250/280/285/330/335 only)
AR-505
10/8/1999
7 – 4
Page of 51
Display