Note for assembling the copy lamp unit
Move the copy lamp unit to the paper exit side, and fix the copy lamp
unit with the harness guide so that the distance between the copy
lamp harness and the lower frame is about 24
±
2mm, (25 ~ 30mm)
with the copy lamp harness extended.
After fixing, manually shift the copy lamp unit a few times to check
that it moves smoothly. 
If the copy lamp harness is loosely fixed, the copy lamp unit may
jump up when reading, resulting in abnormal reading. 
AR-280/285/335
AR-250/281/286/336/405/501/505
(2) Vertical image distortion balance adjustment
(No. 2/3 mirror base unit installing position
adjustment)
This adjustment is to adjust the parallelism of the mirror base to the
OPC drum surface and the original surface. 
1) Manually turn the mirror base drive pulley to bring mirror base B
into contact with mirror base positioning plate. 
If, at that time, the front frame side and the frame side of mirror
base B are brought into contact with the mirror base positioning
plate simultaneously, the parallelism is correct and there is no
need for adjustment. 
Illust: AR-280
24±2mm
25~30mm
AR-505
6 – 8
8/18/1999