AR-505 (serv.man8). AR505 Service Manual-Setting Adjustments - Sharp Copying Equipment Service Manual (repair manual). Page 23

Read Sharp AR-505 (serv.man8) Service Manual online

(Adjustment procedure)
1) Perform adjustment 1 to adjust the distortion in the X section. 
 Adjustment reference 
When the hinge base T section dimension is changed by 1mm, the X
dimension is changed by 0.5 
~
 0.7mm.
2) If the distortion in the Y section cannot be adjusted with adjust-
ment 1, perform adjustment 2. 
 Adjustment reference 
When the hinge a section dimension is changed by 1mm, the Y
dimension is changed by 0.2 
~
 0.4mm.
(Copy image pattern 3)
(Adjustment procedure)
1) Perform adjustment 2 to adjust the distortion in the Y section.
 Adjustment reference 
When the hinge section a dimension is changed by 1mm, the Y
dimension is changed by 0.2 
~
 0.4mm. 
(Copy image pattern 4) 
(Adjustment procedure)
1) Perform adjustment 2 to adjust the distortion in the Y section.
 Adjustment reference 
When the hinge section a dimension is changed by 1mm, the Y
dimension is changed by 0.2 
~
 0.4mm. 
(Copy image pattern 5)
(Adjustment procedure)
1) Perform adjustment 1 to adjust the distortion in the X section. 
 Adjustment reference 
When the hinge base T section dimension is changed by 1mm, the X
dimension is changed by 0.5 
~
 0.7mm.
2) If the distortion in the Y section cannot be adjusted with adjust-
ment 1, perform adjustment 2. 
 Adjustment reference 
When the hinge section a dimension is changed by 1mm, the Y
dimension is changed by 0.2 
~
 0.4mm,
(Copy image pattern 6)
(Adjustment procedure)
1) Perform adjustment 1 to adjust the distortion in the X section. 
 Adjustment reference 
When the hinge base T section dimension is changed by 1mm, the X
dimension is changed by 0.5 
~
 0.7mm.
2) If the distortion in the Y section cannot be adjusted with adjust-
ment 1, perform adjustment 2. 
 Adjustment reference 
When the hinge section a dimension is changed by 1mm, the Y
dimension is changed by 0.2 
~
 0.4mm,
(Copy image pattern 7)
(Adjustment procedure)
1) Perform adjustment 1 to adjust the distortion in the X section. 
 Adjustment reference 
When the hinge base T section dimension is changed by 1mm, the X
dimension is changed by 0.5 
~
 0.7mm.
2) If the distortion in the Y section cannot be adjusted with adjust-
ment 1, perform adjustment 2. 
 Adjustment reference 
When the hinge base T dimension is changed by 1mm, the Y dimen-
sion is changed by 0.2 
~
 0.4mm,
Y
Copy surface
3
Copy surface
Y
4
Document feed direction
Copy surface
Y
X
5
Copy surface
Y
X
6
Y
X
Copy surface
7
AR-505
6 – 22
8/6/1999
Page of 32