[9] TROUBLE CODE LIST
1. Trouble code
Trouble
code
Content of trouble
Remark
Trouble
detection
C1
00
MC trouble
PCU
C2
00
TC trouble
PCU
E7
00
ICU communication trouble
ICU
01
Image data memory trouble
ICU
02
Laser trouble
ICU
03
HDD trouble
ICU
10
Shading trouble (Black correction)
ICU
11
Shading trouble (White correction)
ICU
13
CCD light quantity check error
ICU
90
ICU communication trouble
PCU
F1
00
Finisher communication trouble
PCU
01
Finisher 1 jogger shift trouble / Finisher
2 alignment section abnormality
FIN
02
Finisher transport motor abnormality
FIN
03
Sorter guide bar oscillation motor
trouble
SOT
04
Finisher 1 elevator lower limit detection /
Finisher 2 stack tray lower limit detection
FIN
05
Finisher 1 elevator home / Finisher 2
stack tray sensor abnormality
FIN
06
Finisher shift motor abnormality
FIN
08
Finisher staple shift motor trouble
FIN
10
Finisher staple unit operation trouble
FIN
11
Finisher 1 pusher motor trouble /
Finisher 2 boomerang rotation
abnormality
FIN
14
Finisher 2 stack tray abnormality
FIN
15
Finisher 1 elevator motor trouble /
Finisher 2 stack tray motor lock
FIN
16
Staple sorter holding moter trouble
SOT
17
ST paper exit roller pressure release
trouble
FIN
18
Tray 3 paper exit paddler operation
trouble
FIN
50
Non-suport trouble in automatic
detection of option connection  (Sorter,
finisher)
PCU
80
Finisher power not supplied
FIN
F2
00
Toner control sensor open
PCU
02
Toner motor connector unconnected
PCU
31
Process control trouble (OPC drum
surface reflection rate abnormality)
PCU
32
Process control trouble (Drum marking
scanning trouble)
PCU
37
Drum marking sensor gain adjustment
error
PCU
39
Process thermistor breakdown
PCU
F3
12
Copier top stage CS lift up trouble
PCU
22
Copier bottom stage CS lift up trouble
PCU
F9
00
Printer communication trouble
ICU
01
PRT DRAM trouble
PRT
02
PRT Centroport check error
PRT
03
Network card trouble
04
Printer program error
10
PRT SCSI LSI abnormality
ICU
90
Printer communication trouble
PRT
H2
00
Thermistor open (HL1)
PCU
01
Thermistor open (HL2)
PCU
H3
00
Heat roller high temperature detection
(HL1)
PCU
01
Heat roller high temperature detection
(HL2)
PCU
H4
00
Heat roller low temperature detection
(HL1)
PCU
01
Heat roller low temperature detection
(HL2)
PCU
Trouble
code
Content of trouble
Remark
Trouble
detection
H5
01
3 continuous POD1 not-reaching JAM
detection
PCU
02
Fusing thermistor abnormality
PCU
L1
00
Scanner feed trouble
PCU
L3
00
Scanner return trouble
PCU
L4
01
Main motor lock detection
PCU
L6
10
Polygon motor lock detection
ICU
L8
01
No full-wave signal
PCU
02
Full-wave signal width abnormality
PCU
U2
00
EEPROM read/write error
ICU
11
Counter check sum error (EEPROM)
ICU
12
Adjustment value check sum error
(EEPROM)
ICU
U4
02
ADU alignment plate operation
abnormality
PCU
03
ADU rear edge plate operation
abnormality
PCU
U5
00
RADF/SPF/RSPF communication
trouble
PCU
01
RADF resist sensor trouble
RADF
02
RADF eject/inversion sensor trouble
RADF
03
RADF timing sensor trouble
RADF
06
RSPF post-separation sensor trouble
RSPF
07
RSPF read sensor trouble
RSPF
08
RSPF SB sensor trouble
RSPF
11
RADF paper feed motor operation
abnormality
RADF
16
RSPF fan motor operation abnormality
RSPF
U6
00
Desk communication trouble
PCU
01
Desk 1 CS lift up trouble
Desk
02
Desk 2 CS lift up trouble
Desk
03
Desk 3 CS lift up trouble
Desk
08
Desk 24V power abnormality
Desk
09
LCC lift motor trouble
LCC
10
Desk transport motor trouble
Desk
20
LCC communication trouble
PCU
21
LCC transport motor trouble
LCC
22
LCC 24V power abnormality
LCC
50
Non-suport trouble in automatic
detection of option connection (Desk
unit)
PCU
51
Non-suport trouble in automatic
detection of option connection (LCC
unit)
PCU
U7
00
RIC communication trouble
PCU
U9
00
Operation control communication
trouble
ICU
90
Operation control communication
trouble
OPE
EE
EL Auto developing adjustment trouble
(Overtoner)
In SIM only
PCU
EU Auto developing adjustment trouble
(Undertoner)
In SIM only
PCU
FC
00
ASK/IrDA modulation LSI reset error
01
ASK/IrDA switch error
PC
Personal counter not installed
ICU
PF
RIC copy inhibit command
reception
ICU
– –
Auditor not ready
ICU