IC-22
SHARP ELECTRONICS (UK) LTD
DOCUMENT SYSTEMS GROUP
52
VERSION 1C
MARCH 2002
11.
Adjust all RADF sensors using Simulation 53-02.
Once the above settings have all been input, check the following Test
Simulation settings by comparing the Data Sheets:-
Simulation settings by comparing the Data Sheets:-
Simulation 8-01 & 8-02
DV & HV output settings.
Simulation 26-35
Error trouble count.
Simulation
46 Exposure
settings.
Simulation 50
Lead edge and void settings.
Simulation 51
Resist roller buckle.
Cougar Total Counter Setting
Re-enter the following machine meter readings from the engine data print:-
Total
Counter Simulation
81
Maintenance
Counter
Simulation
82
“Copies”
Counter
Simulation
83-06
“Printer”
Counter
Simulation
83-10
“Others”
Counter
Simulation
83-12
“Scan” Counter
Simulation 83-13
Developer Counter
Simulation 85
Note:
For Non Cougar 2000 models (eg AR335), the “Copy” counter reading that is
obtained by the customer (by holding down the Copy button on the operation
display) can only be re-entered in “Hex Value” by using Test Simulation 79.
obtained by the customer (by holding down the Copy button on the operation
display) can only be re-entered in “Hex Value” by using Test Simulation 79.
Example 1:-
If the count is 1,500 , the Hex value of “5DC” is to be entered within the addresses
0052 ~ 0055 as follows:–
0052 ~ 0055 as follows:–
Input 00
in address 0052
Input 00
in address 0053
Input 05
in address 0054
Input DC
in address 0055
Cont’d